Start up:
Attention:
In order to prevent your hearing from being stressed too much by the very loud alarm tone, do not hold
the device close to your head during the function check! To avoid frightening noise-sensitive persons such as small
children, do not hold the unit in the same room during the function check!
Attention:
Check the function of the smoke detector weekly!
Functional check:
After inserting the battery, check the device for proper function. To do this, hold down the TEST button for approx.
5s. The alarm tone sounds and the LED lights up red. This is to check whether the electronics, the smoke detector's
alarm unit and the battery are functioning. The alarm tone stops immediately after releasing the TEST button.
Note: If neither the alarm sounds nor the LED flashes, the battery is may be empty or the device may be defective.
In case of a defect, replace it with a new functional device
Recurrent self-test of the smoke alarm detector on its function:
The smoke alarm detector performs every 30-40 seconds a self-test. You can see this by a short blink of the LED.
Explanation of the LED modes :
LED flashes every 32 seconds:
LED flashes every second and alarm sounds:
LED flashes every 32 seconds and a short
alarm tone sounds:
Installation (Fig.8) :
1: Dowel
2. Mounting base
3. Holes for screws for fixing
4: Screw
5: Retainer of the bayonet connection
Attention:
Before drilling the mounting holes, make sure that there are no gas, electricity or water pipes at the
drilling location that could be damaged by this!
Since smoke rises to the top and spreads horizontally, install the smoke detector in the middle of the room if possible.
Observe a minimum distance of 0.5m from the side wall and 0.6m from the corner of the room, as well as a maximum
installation height of 6m (see Fig.6).
▪
Remove the mounting plate located on the back of the housing by turning it counterclockwise.
▪
Select an easily accessible installation location, as the smoke alarm detector must be checked weekly for
proper functioning!
▪
Hold the mounting base to the position on the ceiling where you want to attach the unit. Then draw the holes
for the drill holes on the ceiling with a pencil.
▪
Then drill two holes (Ø 6mm). Take the two plugs included in the delivery and insert them into the drilled
holes.
▪
Screw the mounting base to the ceiling. The screws are included in the delivery.
▪
Attach the housing to the mounting base by turning it clockwise until it clicks into place.
The smoke alarm detector is working properly..
TEST button is pressed or the alarm has been triggered by
smoke.
Battery is low.
14