Operation And Storage - Mercalor MT01549 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATION AND STORAGE

VENTILATION
• During operation, the cooker consumes oxygen, which is why the cooker must be used in a
well-ventilated room to prevent combustion. For this reason, the cooker must be used in a
well-ventilated room to avoid combustion, and with good ventilation there can be no
condensation.
CYLINDER CONNECTION
• Use a regulator approved for the pressure of the gas cylinder and a certified hose,
recommended to be no longer than 1.5m. When connecting the regulator to the cylinder, avoid
kinking the hose.
• Place the cylinder on the back of the cooker and close the cover. First check the regulator for
gas leaks with a brush dampened with soapy water. Never use a match or a lighter.
• If there is a gas leak, bubbles will form; in the event of a gas leak, close the regulator.
INTRODUCTION
1. The heater has 3 settings: On (Pos.1) Minimum temperature (Pos.2) Medium temperature
(Pos.3) Maximum temperature (Pos.4)
2. Open the regulator.
TO LIGHT THE COOKER
1. With one hand press the control button (Pos.1) for 10 seconds and with the thumb of the other
hand press the spark button to ignite the flame (red button).
2. Continue this procedure until the panel lights up. Once the flame is lit, release the
The spark button and continue to press the control button for 20 seconds.
3. Set the control knob to the medium temperature position.
4. If the pilot flame goes out, repeat this procedure.