Measuring range setting
Configurations
From 0 to +50 °C
1
2
Combinations
3
4
Unit of measurement setting
To set the unit of measurement, put the on-off switch
4 as shown in the following table.
Configuration via LCC-S software (option)
An easy and friendly configuration with the software!
It is possible to configure intermediate ranges.
The minimum difference between the high range and the
low range is 20.
Example: for a 0-100 °C transmitter, the minimum delta of the range is
20 °C. It is then possible to configure the transmitter from 0 to +100 °C,
or from 0 to +20 °C, etc.
To access the configuration via software:
Set the DIP switches as shown beside.
Connect the cable of the LCC-S to the connection of the transmitter.
The configuration of the parameters can be done either with the
DIP switch or via software (you can not combine both solutions).
Mounting
To install the transmitter, mount the ABS plate
on the wall (drilling: Ø6 mm, screws and pins are
supplied).
Insert the transmitter on the fixing plate (see A
on the drawing beside). Rotate the housing in
clockwise direction until you hear a "click" which
confirms that the transmitter is correctly installed.
The mounting plate is not available
for ambient models. 4 fixing holes inside
the back housing can be used to install the
transmitter on the required location.
Maintenance: please avoid any aggressive
solvent. Please protect the transmitter
and its probes from any cleaning product
containing formalin, that may be used for
cleaning rooms or ducts.
To set a measuring range, put the switches 1, 2 and 3 of the measuring
ranges as shown in the following table.
From -20 to +80 °C From -50 to +50 °C From 0 to +100 °C From 0 to +200 °C From 0 to +400 °C
1
1
2
2
3
3
4
4
Configurations
Combinations
14 mm
Precautions for use: please always use the device
in accordance with its intended use and within
parameters described in the technical features in order
not to compromise the protection ensured by the
device.
1
1
2
2
3
3
4
4
°C
1
2
3
4
PC configuration
1
2
3
4
Left switch
Please refer to the
optional LCC-S
software to make the
configuration.
75 mm
37.5 mm
40 mm
A
A
7.5 mm
1
2
3
4
°F
1
2
3
4
1
2
3
4
Right switch
8 mm
4.5 mm