Specifications are subject to change without notice. These products are not intended for use as critical components in life support or nuclear systems.
Página 1
Maximum output Peak output Product Reference Output voltages voltage power power (10 sec.) EDT-150-5191 230Vac 12V/48V/48V 150W 275W Specifications are subject to change without notice. These products are not intended for use as critical components in life support or nuclear systems.
Página 2
INPUT Rated input voltage 230Vac Input voltage range 184 … 264Vac Mains frequency range 47 … 63Hz Inrush current <12A Power factor >0.6 OUTPUTS Rated output voltage 13.6 Output voltage range 9.6 … 15 ± 1 ± 1 Maximum permanent current 15.7 0.83 Maximum peak current (10s)
Página 3
Contact closed in case of alarm: • Battery failure Urgent failure alarm (URG) • Charger failure • Failures involving battery disconnection or charging Contact closed in case of alarm: • Battery voltage above its maximum value Non-Urgent Failure alarm (NUR) •...
BLOCK DIAGRAM DESCRIPTION The equipment consists of a rectifier-charger that, in case of having input AC voltage, provides a regulated output voltage and charges the battery in a controlled way. The equipment comprises a switched power supply and a three-state battery charger. It also incorporates alarm circuits that signal failures in the input voltage, in the battery or in the charger.
ETHERNET PORT INSTALLATION • The configuration and monitoring of the status of the • Perform the installation of the equipment following the equipment is carried out through the Ethernet port. The connection drawings. The value of the charging current can system has the following characteristics: be changed from the default value via the Ethernet •...
Página 6
DIMENSIONS Dimensions in mm. Table 1 - Mechanical and temperature tests Acceptance Tests Severity Conditions criteria Temperature: 40ºC Humid heat Humidity: 93% Equipment connected Criterion A Duration of the test: 4 days (accelerated aging) Temperature: 60º C. Dry heat Equipment connected Criterion A Duration of the test: 16 hours.
Página 7
Table 2 - EMC Specification: Emissions Test Port Regulations EN 55032 class B. Measurements Radiated emissions Enclosure made at 3m between antenna and equipment with boundary conversion 12V and 48V power terminals EN 55032 Class A Conducted emissions Alternating input power terminals EN 55032 Class B Table 3 - EMC Specification: Immunity TEST...
Insulation tests Method Equipment disconnected from power, earthed, with the terminals of each group short-circuited together. I/O groups formed: AC power terminals. DC power terminals. Ethernet and Alarms. Insulation resistance > 100Mohm with ±500Vdc between each group and earth. Reading performed 5 seconds after applying voltage. Note: The test is performed at the beginning and end of all isolation measures.
Página 9
For the fulfillment of this declaration the product must be used only for the aim that has been conceived, considering the limitations established in the instructions manual or datasheet. L'Hospitalet de Llobregat, 31-05-2021 Miguel Angel Fernandez PREMIUM S.A. is an ISO9001and ISO14001 Chief Research & Development Officer certified company by Bureau Veritas 9 / 18 www.premiumpsu.com...
(10 seg.) EDT-150-5191 230Vac 12V/48V/48V 150W 275W Specifications are subject to change without notice. These products are not intended for use as critical components in life support or nuclear systems.
ENTRADA Tensión de entrada nominal 230Vac Rango de tensión de entrada 184 … 264Vac Rango de frecuencia de red 47 … 63Hz Corriente de arranque <12A Factor de potencia >0.6 SALIDA Tensión de salida nominal 13.6 Rango de tensión de salida 9.6 …...
Contacto cerrado en caso de alarma: Alarma Fallo de Red (FAC) • Tensión de entrada fuera de rango • Sin tensión a la entrada Contacto cerrado en caso de alarma: • Fallo de batería Alarma Fallo Urgente (URG) • Fallos internos del equipo •...
DIAGRAMA DE BLOQUES DESCRIPCIÓN El equipo consiste en un cargador-rectificador que, en caso de tener tensión CA de entrada, proporciona una tensión de salida regulada y carga la batería de forma controlada. El equipo comprende una fuente de alimentación conmutada y un cargador de baterías de tres estados.
PUERTO ETHERNET INSTALACIÓN • La configuración y monitorización de estado del equipo se • Realizar la instalación del equipo siguiendo el diagrama de lleva a cabo a través del puerto Ethernet. El sistema conexionado. El valor de la corriente de carga puede presenta las siguientes características: modificarse respecto al valor por defecto a través de la •...
DIMENSIONES Dimensiones en mm. Tabla 4 - Ensayos mecánicos y de temperatura Criterios Ensayos Severidad Condiciones aceptación Temperatura: 40ºC Calor húmedo Humedad: 93% Equipo conectado Criterio A Duración de la prueba: 4 días (envejecimiento acelerado) Temperatura: 60º C. Calor seco Equipo conectado Criterio A Duración de la prueba: 16 horas.
Página 16
Tabla 5 - Especificación EMC: Emisiones Test Puerto Normativa EN 55032 clase B. Medidas Emisiones radiadas Envolvente realizadas a 3m entre antena y el equipo con conversión de límites Bornes de alimentación de 12V y 48V EN 55032 clase A Emisiones conducidas Bornes de alimentación entrada alterna EN 55032 clase B...
Ensayos de aislamiento Método Equipo desconectado de la alimentación, puesto a tierra, con los terminales de cada grupo cortocircuitados entre sí. Grupos de E/S formados: Terminales de alimentación CA. Terminales de alimentación CC. Ethernet y Alarmas. Resistencia de aislamiento > 100Mohm con ±500Vcc entre cada grupo y tierra. Lectura realizada 5 segundos después de aplicar tensión. Nota: El ensayo se realiza al principio y al final de todas las de aislamiento La diferencia entre ambas medidas es <20%.
Página 18
L’Hospitalet de Llobregat, 31-05-2021 Miguel Angel Fernandez PREMIUM S.A. is an ISO9001and ISO14001 Chief Research & Development Officer certified company by Bureau Veritas 18 / 18...