INSTALLING THE POWER SUPPLY
Select a convenient well-ventilated location within one metre of filter equipment and mount the Power
Supply vertically onto a post or wall 1.5 metres above ground level. The Power Supply should not be
located within 3 meters of the pool water. Connect Power Supply into a suitable weatherproof outlet
or an independent control box. The Unit must be kept away from acid and other chemical storage areas.
Acid and chemical vapours will corrode the electronics inside the Unit. It must also be kept away from heat
sources. Good ventilation is necessary for correct operation (See installation diagram on page 14).
Two self-tapping screws and wall plugs have been provided for fast and simple installation. Use a 7mm
masonry drill bit when fitting Power Supply to a brick or concrete wall. When mounting to a post drill pilot holes
and fit screws provided. Once screws are in position simply hang chlorinator via bracket on back of Unit.
CONNECTING THE ELECTROLYTIC CELL TO THE POWER SUPPLY
The Power Supply is fitted with a flexible lead
terminated with connectors. These must be
correctly fitted to the connections on the underside
of the Cell. Fit black connectors to the outer
titanium rods. Fit the white connector the middle
titanium rod. Ensure the connectors are tight when
inserted.
Important: The Cell has to be connected as shown.
Note: The Cell is supplied with a paddle type
flow switch, which is to be installed on the Cell
as shown in the diagram on pages 6 and 7.
IMPORTANT: The flow switch must be mounted with the highlighted arrow on top of the
switch pointing in the direction of flow.
CONNECTING THE FLOW SWITCH TO THE POWER SUPPLY
Join the connector on the flow switch and the connector on the cell cable together. They will clip together.
Note: The bolt and saddle clamp included, is for a connection to an independent earth.
IMPORTANT: Do not operate the unit with pool isolation valves closed as possible pressure build-
up may cause the cell the break open. Such damage will not be covered under warranty. For valve
use, refer to your pool installer/builder.