9
Troubleshooting
EN
If the trouble you are experiencing is not listed below or you are unable to remedy the problem by
yourself, please contact your fischer contact. Stop using the tool immediately.
Malfunction
Nails are driven not deep
enough.
Nails are driven too deep.
Nails bend.
The fuel cell is empty
before all nails of a package
were used.
40
Possible cause
Driving power is too low.
The nails are too long.
The working surface is too hard.
Driving power is too high.
The nails are too short.
Driving power is too low.
The nails are too long.
High gas consumption due to
a frequent actuation of the tool
through pressing it against the
working surface without driving
a nail.
Action to be taken
→ Turn the depth adjustment wheel to reduce
the length of the nose piece.
→ Use shorter or smooth nails.
→ Use a different fastening method.
→ Turn the depth adjustment wheel to
increase the length of the nose piece.
→ Use longer nails or nails with ring shank.
→ Turn the depth adjustment wheel to reduce
the length of the nose piece.
→ Use shorter or smooth nails and check the
wood for knots.
→ Avoid actuation of the tool without driving
a nail.