4. Remove the water-return unit and nozzle for cleaning and removing dirt.
5. Do not frequently wipe the gold and chrome plated parts (do not contact it with organic solvent).
6. Please keep blunt and knife away from the surface, and butt or the things over 60 degree should be away from
that too.
7. One time to check button of electricity leakage every month.
8. Make frequent checks on the electrical wires, buttons, connectors always to see if they are bitten by rats or
worms.
9. Make frequent checks on the feed pipe and drain pipe always to see if there is some parts broken or bended
make sure it is smooth.
10. When storing the products, do not put converted and overlapped, make sure they are far away from formic
acid and methanal as well as any other organic solvent.
11. If they are needed to be carried, do take those actions lightly, in case of high pressure, mechanical impact
strength and succession.
12. If the bathtub is not to be used for a long time, dry inside the bathtub and make the circumstance dry and
ventilated as well as no corrosive gas.
Instructions on Maintenance
1. Replace the massage water pump: cut off power supply, open the bathtub side plate, drain empty the SPA's
water, remove the wires and open the water pump, loosen the fixed bolts and take out the water pump, after
replacing the pump, install power wire, fix the bolts, put into small amount of water into the bathtub, check if
there's leakage at the pump, and then install the side plate of the bathtub.
2. Replace the filter water pump: cut off power supply, open the bathtub side plate, turn off the valves on both
ends of water pump, remove the wires and open the water pump, loosen the fixed bolts and take out the water
pump, after replacing the pump, install power wire, fix the bolts, put into small amount of water into the bathtub,
turn on the valve, check if there's leakage at the pump, and then install the side plate of SPA.
3. Replace the thermostat: cut off power supply, open the bathtub side plate, turn off the valves on both ends of
thermostat, remove the wires, loosen the fixed bolts and take out the thermostat, after replacement, install
power wire, fix the bolts, put into small amount of water into the bathtub, turn on the valve, check if there's
leakage at the pump, and then install the side plate of the bathtub.
4. Replace the filter core: cut off power supply, open the bathtub side plate, turn off the valves, loosen the bolts on
top of the filter, take out the filter, and remove dirt on bottom of the filter.
5. Anti-frozen of filter: In some area, water may be frozen in winter, under this case, please stop using filter, to
remove it and clean the core, store it in safe place or move the filter core to interior. Or keep the SPA at standby
state.
Troubleshooting
Faults
No reaction for panel
Key
No power supply
Nozzle doesn't spray
water
Reason
1. Panel was locked
2. Panel is broken
1. There's problem for the
power circuit;
2. Protective switch is cut off.
1. There's problem for power
supply of water pump;
2. Water pump is not started.
3. Massage water pump is
25
Unlock the panel
Change panel
Check the circuit;
Check and remove short
circuit,Connect the protective switch
Check and connect the power wire
Check the massage water pump
Replace the massage water pump
Purify pipe by taking the loose joint part
Solution