• MFITVJNSTRUCIIPNS.
The manufacturer advises the correct use of Luminaires (lighting fixtures)! Therefore always follow these
instructions to ensure correct and safe Installation and functioning of the luminaire and keep it for future
reference.Turn off electrical power at main fuse or circuit breaker box before commencing installation, maintenance
or
repair.
If in doubt, consult a qualified electrician or contact your retail outlet. Ensure that you always install the
luminaire to the local electrical
code.
Certain regulations indicate that luminaires should be Installed by a qualified
electrician. Observe the correct color of the wiring before
installation:
white (N), black (L) and green or bare copper
wire
(Ground).
Do not connect this luminaire to a
non-
grounded electrical
system.
WARNING: Installing this fixture
in a non-grounded electrical system could allow metal parts of the lumlnaire to carry electrical current If any wires
or wire connections become broken or
loose.
Under this condition, anyone coming in contact with the luminaire is
subject to electric shock which could cause injury or death. Always use wire nuts/connectors rated for the correct
gauge and number of wires
used.
CAUTION: Be certain that no bare wire strands are exposed outside of the wire
nuts/connections (if applicable). Be careful not to damage or cut the wire insulation (covering) during
installation.
Do not permit wires to contact any sharp
edges.
Do not remove thermal insulation pad(s). Doing so will result in
increased temperatures and possible risk of
fire.
Maintain Interior lighting with a dry cloth duster. do not use
abrasives or solvents.Avoid liquid on all electrical parts. Always consider all the technical specifications of the
luminaire.Verify the stated icons on the identification label on the luminaire and the icons that are shown in part A
of your safety
instructions.
ATTENTION
: Below you will find all the explanations with numeric reference to the
icons respectively in front of these
PART-
B safety
Instructions.
Applicable icons to your fixture are shown in
PART-
A
safety Instructions.
1) This product should only be installed indoors. 2) The product is suitable for outdoor
usage.
3) Only suitable for
dry locations. 4) Suitable for damp
locations.
5) Suitable for wet
locations.
6) Luminaire is suitable for base up
mounting.
7)
Luminaire is suitable for base down mounting. 8) Luminaire is suitable for horizontal
mounting.
9) The luminaire is only suitable for fixing to the
ceiling.
10) The luminaire is only suitable for fixing to the
wall.
11) The luminaire is suitable for fixing to the wall and to the
ceiling.
12) Always observe the minimum distance
between the lamp and the surface being lit as indicated on the
icon.
13) Free air space of at least 4 inches must be
kept between top of shade and bottom of canopy. 14) Immediately replace a cracked or broken safety glass and
use only manufacturer approved
parts.
15) Strip the wire as indicated in the
diagram.
16) Use heat-resistant cable
for wiring the luminaire into the
mains.
17) MAX
. ... W:
only use lamps suitable for this luminaire and keep within the
maximum specified wattage. 18) This product is not suitable for children under 14
years.
19) The Luminaire has a
ground conductor identified with green insulation or bare copper
wire.
20) The luminaire is only suitable for a lamp
with
built-
in safety or a low pressure lamp. An extra safety glass is not necessary. 21) The luminaire is equipped
with a
fuse.
If the luminaire is out of order after the bulb has been
replaced,
the internal fuse has to be
replaced.
If contact with the internal wiring can be made during this operation, this should be done by a competent
electrician. 22) The luminaire can be used with a dimming circuit. Consult a qualified electrician for choosing the
right type (especially important for low voltage
luminaires).
23) The Luminaire cannot be used with a dimming
circuit. 24) The luminaire is dimmable with the supplied dimmer ONLY. Do not connect to an additional
dimmer.
25) The dimmability features depend on the chosen
lamp.
More information on the dimmability features is
available in the information pack provided with the
bulb.
26) Luminaire with time and light setting
options.
Minimum and maximum will be shown in the icon in part
A.
27) The luminaire can be placed at a maximum of 20ft
height. 28) To reach an optimal
working,
you have to place the luminaire on the height mentioned in the icon. The
maximum and minimum reach of the detector is also mentioned in the icon in part
A.
29) The standard active range
of vision of the detector covers the given degrees mentioned in the icon. 30) Ensure that you don't drill through
electrical wires or any other obstruction in the wall or ceiling during installation! 31) This luminaire contains in some
places very hot parts. 32) Product to be installed by two
people.
33) To avoid
corrosion,
clean the luminaire a
minimum of 2 times per year with a soft cloth and a neutral detergent. (4 times in coastal or industrial areas). 34)
The product is for indoor use
only.
Do not use in wet locations, areas directly exposed to water or outdoors.
35) The product is ZigBee
certified.
Zigbee is an open standard for indoor wireless
communication.
All Philips
ZigBee Certified products can be connected with other Philips ZigBee Certified products. 36)
Bluetooth•
enabled
product. The Bluetooth
9
word mark and logos are registered trademarks owned by Bluetooth SIG,
Inc.
and any use
of such marks by Signify is under license. Other trademarks and trade names are those of their respective
owners.
Hue Personal Wireless Lighting is a trademark owned by Signify Holding
B.V.
Please go to www.philips-hue com to
learn more about Hue and how to use it.
This device complies with Part 15 of the FCC Rules and with RSS of Industry Canada. Operation is subject to the
following two conditions:
(1)
this device may not cause harmful
interference,
and (2) this device must accept any
interference received, including interference that may cause undesired
operation.
This equipment has been tested
and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules These limits
are designed to provide reasonable protection against harmful interference in a residential
installation.
This device
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions. may cause harmful interference to radio
communications.
This Class B digital apparatus complies with CAN ICES-005. This digital apparatus does not exceed the class B limits
for
radio-
noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian