Eliminating faults or malfunctions
Fault code
E6
Replace the battery
Make sure that the current supply for the torque
wrench is guaranteed. Use only a lithium battery,
3.6 V, type 14500.
CAUTION
Risk of injury due to exploding
batteries.
Do not charge batteries.
Replace empty batteries with full
batteries of the same type.
Turn the cover counter-clockwise to stop.
Remove the cover.
Remove the spent battery.
Insert the fresh battery as shown, with the positive
terminal first.
Insert the lock in the cover into the battery
compartment recesses.
Press the cover on gently.
Turn the cover clockwise to stop.
Signals
Cause
Red LED lights up
Electronic fault
and three acoustic
signals per second
are audible
Remedy
Send the torque wrench to
the manufacturer for repair.
Taring the torque wrench manually
Manual taring is necessary if, for example, a value
which is not zero is shown on the display after
bolting processes.
ATTENTION
Incorrect measurements due to moving
or loading the torque wrench during
the taring process.
Make sure that the torque wrench is
not moved or loaded during taring.
Store the torque wrench so that the
square drive lies free.
Place the switched on torque wrench onto a flat
surface.
No lateral forces must act on the square drive
during taring. To ensure this, the square drive must
e.g. lie over the edge of a bench.
Press the operating button for approx. two
seconds.
The
symbol is shown on the display. The torque
wrench is tared within a few seconds. "0", the set
function mode and the selected unit are then shown
on the display. The torque wrench is tared and
ready for use.
23