Getting to know your headlamp
(A) Button A
(B) Button B
(C) Bracket
(D) Flood light
Operating instruction
Spot light
• Single press (A) to cycle through settings.
Low > Med > High > Ultra-High > Off
• Double press (A) at any time to turn off and
memorizes last selection.
Flood light
• Single press (B) to cycle through settings.
Ultra-low > Low > Med > High > Off
• Double press (B) at any time to turn off and
memorized last selection.
Turbo
• Press and hold (A) or (B) for > 1 sec to
activate Turbo mode from any light setting.
• Double press (A) or (B) to turn off settings.

Battery indicator

• When headlamp off double-press (A) or (B) to check battery level.
Solid green
Solid red
Red ashes 3 times
• Low warning indicator – When battery is below 35%, the light in use will ash twice every 5
minutes.

Over-heat protection

The output will drop down one step if overheating occurs to protect the headlamp.
Specifications
ANSI FL1 Standard
Output Lumen
Runtime
Beam Distance
Impact Resistance
Waterproof
Weight
: 137g (with 18650 battery)
Dimensions
: 91.5 x 52.2 x 42 mm
LED
: OSRAM LED
Material
: Die-cast aluminium
Circuit
: Digitally regulated
Battery
: 1 x 18650 Li-ion battery or 2 x 3V CR123A
Battery protection
: Over-charge and over-discharge
Note
1. The above speci cations are tested by GP internal laboratory using GP 18650-26FCP 3.6V
2550mAh rechargeable Li-ion battery at temperature 20 - 25°C and humidity ranging from 40% -
80%.
2. The performance may vary according to working environments and actual battery conditions.
Usage and Care
• Do not dismantle headlamp as this can cause harm to the headlamp and the person and will void
the warranty.
• This has a high lumen output so do not shine directly into anyone's eyes as it may cause harm
and injury.
• Use suggested batteries for this product for your own safety.
• Do not use cleaning agents that may damage the products. Use soft cloth to avoid scratching.
• When charging always connect charge port carefully to avoid water and other liquids getting into
the port which may cause damage to the unit and battery.
• Seek medical advice immediately if a battery has been swallowed.
• In the event of a cell leaking, do not allow the liquid to come in contact with the skin or eyes. If
contact has been made, wash the affected area with copious amounts of water and seek medical
advice.
• When possible, remove the battery from the equipment when not in use.
• Dispose of battery properly.
Caution
• Charging incorrect type batteries may lead to explosion, battery rupture or leakage, personal
injury or property damage.
• Do not dispose of batteries in a re or a hot oven, or mechanically crushing or cutting of a battery
that can result in an explosion.
• Leaving a battery in an extremely high temperature or low air pressure surrounding environment
that can result in an explosion or the leakage of ammable liquid or gas.
Over 70%
35% to 70%
Below 35%
Spot
Ultra-High
High
Med
800lm
500lm
150lm
3.5h
4h
6.5h
110m
60m
35m
(E) Unscrew battery cap to change
battery- insert +/-
(F) Battery/Charge indicator
(G) Unscrew to access USB-C charge port
(H) Spot light
SOS & Beacon
• To activate SOS, press and hold (A) or (B)
for 5 sec to activate SOS. Activation can
be from off or when already on.
• To activate Beacon, press (A) and then
press (B) or press (B) and then press (A).
• Press (A) to returns to low spot only.
• Press (B) to returns to ultra-low ood only.
• Double press (A) or (B) to turn off all settings.
Lock-out
• Lock - Press (A) and (B) simultaneously for
3 seconds – LED battery red indicator
ashes twice to con rm lock-out activated.
• Unlock - Press (A) and (B) simultaneously for 3
seconds – LED battery green indicator ashes
twice to con rm lock-out de-activated.
Low
High
40lm
400lm
38h
4.5h
15m
62m
1.5m
IPX8
Flood
Med
Low
Ultra-Low
250lm
40lm
10lm
100h
6h
18.5h
40m
15m
5m
GB