7. OPERATION:
AC Parallel Operation Applications
Generators AGi2100 can be connected to each other to increase the available power
using a parallel cable kit .
Before connection of an appliance or power cord to the generator, follow the
instructions included with the parallel operation cable kit.
TIP:
• Make sure that it is in good working order. A faulty appliance or power cord can
create a potential for electrical shock.
• If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly,
turn it off immediately. Disconnect the appliance and determine whether the
problem is the appliance or if the rated load capacity of the generator has been
exceeded.
• Make sure that the combined electrical ratings of the tools or appliance do not
exceed that of the generator. Never exceed the maximum rated output for more
than 30 minutes. Never connect different generator models.
• For parallel operation, use only a manufacturer approved parallel operation cable
kit for connecting one AGi2100 to another AGi2100 generator.
• Never connect or remove the parallel operation cable when the generator is
running.
• For single generator operation, the parallel operation cable must be removed.
WARNING:
Substantial overloading that continuously lights the overload indicator (red) may
damage the generator. Marginal overloading that temporarily lights the overload
indicator (red) may shorten the service life of the generator.
Limit operation requiring maximum power to 30 minutes.
Maximum power in parallel operation: 4.0 kVA.
For continuous operation, do not exceed the rated power.
Rated power in parallel operation : 3.2 kVA .
The total power requirements (VA) of all appliances connected must be considered.
Appliance and power tool manufacturers usually list rating information near the
model number or serial number.