5
LOCATING MALFUNCTIONS
The device has a green LED on the restart button to inform about alarms.
LED
TIME ON
TIME OFF
Off
Off
Off
Off
15 ms
600 ms
2 flashes
200 ms
200 ms
700 ms
50 ms
15 ms
600 ms
5 flashes
15ms
600 ms
6 flashes
15ms
600 ms
3 flashes
When a failure warning occurs, press the restart button to reset the alarm.
6
INSTRUCTIONS TO ORDER SPARE PARTS
6.1 INSTRUCTIONS TO ORDER SPARE PARTS
1.- Every spare parts order must include PART CODE NUMBER AS STATED IN THE PARTS
LIST. We recommend including the MACHINE SERIAL NUMBER.
2.- The identification plate with serial and model number is located as shown in the point 2 of this
manual.
3.- Let us to know the right shipping instructions, including the wished route, the address and the
consignee complete name.
4.- Do not return the parts without authorisation, the return is done with freight prepaid.
Description
Normal functioning. Status:
Waiting
Normal functioning. Status:
Working
Status: Low battery
Output overload
High temperatura warning
Overheating warning
Battery overvoltage
Short circuit
BATTERY POWERED ELECTRONIC CONVERTER
Action to take
None
None
Charge the battery
Excess of load connected to the
converter / malfunction of the vibrator
connected to it.
You can keep working until overheating
warning.
Clean the device.
If the warning remains contact the
official service.
Clean the device.
If the warning remains contact the
official service.
Send the device to the official service or
a dealer for checking.
Defective poker.
Defective converter.
BOXEL E-BATT
en
11