Control Panel: OPERATION AND FUNCTIONS
ON/OFF
K1
Exit from Menu
User Menu Entry
K2
Probes Menu
Temperature Probe S1
2
Probe S2 Displayed
Spark Function Active
SERV Output Active
5.
FUNCTIONS
ON/OFF
5.1
ON/OFF of the control unit is done by prolonged pressure on the K1
The OFF status is indicated by the lit K1button
The following sequence of messages is displayed when the control unit is turned on
o Product Code F002
o Product Revision
MODES OF OPERATION
5.2
[P17 = 1; INPUT S1 = Probe NTC100K]
It is possible to choose from among three Modes of Operation:
MANUAL: indication light
The fan operates at the speed set by the user in an independent way from the S1 Probe.
AUTOMATIC: indication light
The fan operates at the speed set by the user, if the temperature of the S1 Probe is greater than E01.
PROPORTIONAL: indication light
The fan operates at the speed selected by the temperature control unit, depending on the temperature of the S1 Probe.
The temperature range where the transmission power is active goes from E01 to E01+E50
[P17 = 2; INPUT S1 = Thermostat]
AUTOMATIC: indication light
The fan operates at the speed set by the user, if the temperature of the S1 Probe is greater than E01.
SAFETY FUNCTION [P17 = 1]
5.3
This function is active if P04 = 1 and allows to dissipate the excess heat in the stove.
If the temperature detected by the S1 Probe exceeds the value of the Safety Thermostat E02 and the Fan is switched
off in MANUAL Mode or by the Room Temperature Thermostat, the operation moves to PROPORTIONAL Mode
with a delay of 10 seconds.
ALARM FUNCTION [P17 = 1]
5.4
If the temperature detected by the S1 Probe exceeds the value of the Alarm Thermostat E03
If the P05 = 1 parameter is activated, an acoustic and visual warning is triggered (the temperature flashes on the Display)
SILENCE Function: the acoustic signal can be turned off for 5 minutes by pressing on any button. If the alarm
condition persists, the acoustic signal is reactivated.
The Operation moves to PROPORTIONAL Mode with a delay of 10 seconds.
FAN SAFETY FUNCTION [P17 = 1]
5.5
This function is active if P03 = 1. If the temperature detected by the S1 Probe exceeds the value of the Fan Safety
Thermostat E04, the Fan is switched off to avoid damaging it.
STANDBY FUNCTION [P17 = 1]
5.6
In the case of the device TURNED OFF, if the temperature of the S1 Probe exceeds the value of the E02 or E03 thermostat
The device automatically moves to the ON state
1
2
Fig. 3 Main Screen
r 0.4
; displays the word AUTO
A
On:
Fan On
Flashing:
Fan in Safety mode
MANUAL Mode
AUTOMATIC Mode
PROPORTIONAL Mode
button
Scroll/Increase
K3
Service Grill
Manual Start Damper
K4
Scroll/Decrease
7