PROBES DISPLAY
5.7
The display currently shows the value read from the S1 Probe if P17 = 1
Through a simple click of the K2 key, the temperature of the S2 Probe is displayed (LED
You can exit from this display via the K1 key, scrolling all probes with the K2 key, or automatically after 10 seconds.
If the reading of the probes is lower than the minimum range of the sensor, this message displays the message Lo
If the reading of the probes is higher than the maximum range of the sensor, this message displays the message Hi
SERVICE OUTPUT
5.8
The SERVICE Output is programmable from the Installer MENU of parameter P02:
P02 = 0 DISABLED: the output does not work
P02 = 1 THERMOSTAT: the output is active if the temperature of the S1 Probe is greater than the E07 thermostat
P02 = 2 GRILL: pressing the K3 button for 3 seconds you can turn on or turn off the output
P02 = 3 DAMPER: the output manages a damper for the adjustment of the combustion air
P02 = 4 SPARK: the output manages the spark control
The functions THERMOSTAT AND DAMPER are disabled in the case of P17 = 1.
DAMPER [P17 = 1]
5.9
The Damper is enabled if the parameter P02 = 3
If the output is Active (ON) the Damper is Open, if the output is off (OFF) the Damper is Closed.
The Damper is Open until the temperature of the S1 Probe is lesser than the E06 thermostat. It is closed when that
thermostat is exceeded.
 If P12 = 1 is enabled, the Manual Start function:
If the Temperature of S1 is lower than E05, the Damper is Closed. In the ignition phase of the Stove, pressing the K3 for 3
seconds, it forces the manual opening of the Damper (the LED
thermostat E05, after the t06 time has passed, the Damper Automatically closes.
SPARK Function
5.10
The Damper is enabled if the parameter P02 = 4
By pressing the K1 key the output relative to the Spark kit is activated: the device displays the writing 'Sci' flashing for 2
sec. This indication remains visible until the firebox has turned on.
INPUT S2 CONFIGURATION
5.11
Using parameter P01 you can enable the following connection managers:
 P01 = 0, input S2 = DISABLED
 P01 = 1, input S2 = ROOM TEMP PROBE
 P01 = 2, input S2 = ROOM TEMP THERMOSTAT
SENSOR PROBE/ROOM TEMP THERMOSTAT
5.12
Using parameterP01 it is possible to enable the management of the ROOM TEMPERATURE
If the Temperature of the Room Temperature Probe is greater than the thermostat b01 or the Contact of the External
Temperature Thermostat is Open (the LED
The Fan is switched Off
The Damper is Closed if P02 = 3
FAN STARTING FUNCTION
5.13
This operation allows the Fan to operate at Maximum Speed for a programmable time (t08), every time that it has to start
from a standstill. After the time has lapsed the Fan will resume to programmed speed.
To disable the Fan Starting function, programme the time t08 to t0 seconds.
6.
MENU
MAIN MENU
6.1
It is accessible by pressing the K2 button for 3 seconds
 Always with the K2 key, it scrolls through the various parameters, indicated by the flashing of the associated LED.
 With the keys K3 and K4 you can modify the value of the parameters.
 Press the K2 key to save the new value or wait 10 seconds.
 Press the K1 key to exit without saving.
LED
MANUAL Operation
AUTOMATIC Operation
PROPORTIONAL Operation
Room Temp. Thermostat
8
flashes)
Description
flashes). When the temperature again drops below the
Code
Min
Set
MANU
AUTO
MANU
AUTO
PROP
b01
5
20
flashes).
Probe/Thermostat
Max
U.O.M.
-
PROP
50
[°C]