en-us_main.book.book Page 12 Friday, November 4, 2022 8:08 AM
12 INSTALLATION
Electric Ignition
Select a top burner knob, push down and then
turn counterclockwise to the LITE position.
You can hear a clicking sound indicating proper
operation of the spark module.
Once the air has been purged from the supply
lines, burners should ignite within 4 seconds.
After the burner ignites, rotate the knob out of the
LITE position. Try each burner in succession until
all burners have been checked.
The combustion quality of the burner flames
needs to be confirmed visually.
Yellow flames — Call for
a
service
Yellow tips on outer cones —
b
Normal for LP gas
Soft blue flames — Normal for
c
natural gas
If burner flames look like
is normal for burner flames, depending on the
c
type of gas you use.
With LP gas, some yellow tipping on outer cones is
normal.
8. Adjusting the Surface Burner Low
Flame (Simmer) Setting
1
Light all surface burners.
2
Turn the knob on the burner being adjusted
to LO (LOW).
3
Remove the knob.
4
On dual burner knob rings only, remove the
plastic cover
on the knob ring by turning it
a
counterclockwise.
, call for service.
or
a
b
CLOSE
5
For single-valve burners, insert a small, flat-
blade screwdriver into the valve stem.
For dual-valve burners, insert a small, flat-
blade screwdriver into the hole to the left of
the valve stem.
Single Valve Adjustment Screw
a
Dual Valve Adjustment Screw
b
6
Turn the adjustment screw until the flame
reaches the desired size.
7
Replace the knob.
8
Test the flame stability.
Test 1
• Turn the knob from HI to LOW quickly.
• lf the flame goes out, increase the flame
size and test again.
Test 2
• With the burner on a LOW setting, open and
close the oven or cabinet door quickly.
• If the flame is extinguished by the air
currents created by the door movement,
increase the flame height and test again.
9
Repeat steps 1 - 6 for each surface burner.
10
After setting the low flame, turn off the
burner.
OPEN