Descargar Imprimir esta página

EGAmaster CURVAMATIC-3 Manual De Instrucciones página 9

Publicidad

Idiomas disponibles

Idiomas disponibles

SIZE
1/4
3/8
1/2
3/4
1
1.1/4
1.1/2
2
2.1/2
3
MAINTENANCE
It is very important to use hidraulic oil and not any other type of fluid.
Filter the oil before putting it into the deposit as any foreign substance can damage the O
rings or any of the valves.
The valve (nº50), in position of rest, must be opened and the piston withdraw, to avoid having
pressed the spring of the pistons return.
Before several days without being used, lubricate the end of the piston to avoid corrosions
and seizure while starting again its usage.
ADVICE
Take care while working, don't place your body in front of the machine, that will avoid accidents.
IMPORTANT
When ordering spare parts please indicate its code number and the serial number of the machine.
A) FILLING THE DEPOSIT
Introduce through the plug (nº36) the oil. Introduce through the plug (nº36) the oil. For that, it
is strongly recommended to move back the piston (with the runback roulette), stabilize the pis-
ton horizontally to level the oil fully, insert a rod until a stop is found and measure 1,5cm of oil.
This will be the ideal level of filling.
A
TUBING DIAMETER & THICKNESS DIN-2440
EXTERIOR DIAMETER
GUIDE OF USAGE
13,5
17,2
21,3
26,9
33,7
42,4
48,3
60,3
76,1
88,9
THICKNESS
2,35
2,35
2,65
2,65
3,25
3,25
3,65
3,65
3,65
4,03
9

Publicidad

loading

Este manual también es adecuado para:

60016