5. Before starting the equipment
Before you connect the equipment to the power
supply make sure that the data on the rating plate
are identical to the supply voltage.
•
Check the equipment for damage which may
have occurred in transit. Report any damage
immediately to the transport company which
was used to deliver the compressor.
•
Install the compressor in the vicinity of the
point of consumption.
•
Avoid long air lines and supply lines (extensi-
on cables).
•
Make sure that the intake air is dry and dust
free.
•
Do not install the compressor in a damp or
wet room.
•
The compressor may only be used in suitable
rooms (with good ventilation and an ambient
temperature from +5 °C to 40 °C). There must
be no dust, acids, vapors, explosive gases or
inflammable gases in the room.
•
The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor
in areas where work is conducted with spray-
ed water.
•
Operate the equipment only on a firm, level
surface.
•
Use flexible hoses in order to prevent trans-
mitting unacceptable loads to the pipeline
system at the connection between the com-
pressor system and the pipeline system.
•
It is essential to use separators, traps and
drains which process the liquids produced by
the compressor before the compressor sys-
tem is put into operation.
•
Supply hoses at pressures above 0,7 MPa
(7 bar) should be equipped with a safety
cable (e.g. a wire rope).
Anl_SA_TE_AC_24_Silent_SPK8.indb 27
Anl_SA_TE_AC_24_Silent_SPK8.indb 27
GB
6. Assembly and starting
Important!
You must fully assemble the appliance before
using it for the fi rst time.
6.1 Fitting the supporting feet (4)
Fit the supplied supporting feet (4) as shown in
Fig. 7.
6.2 Fitting the transport handle (9)
Screw the transport handle (9) to the compressor
as shown in Figures 8 to 9.
6.3 Fitting the air fi lter (1)
Use a screwdriver to remove the transportation
cover from the air fi lter connection Screw in the
supplied air fi lter (Fig. 10).
6.4. Power supply
•
The motor is fitted with an overload switch
(Fig. 3/Item 13). If the compressor overloads,
the overload switch will switch off the equip-
ment automatically to protect the compressor
from overheating. If the overload switch trig-
gers, switch off the compressor using the ON/
OFF switch (8) and wait until the compressor
cools down. Then press the overload switch
(13) and restart the compressor.
•
Long supply cables, extensions, cable reels
etc. cause a drop in voltage and can impede
motor start-up.
•
At low temperatures below +5°C, sluggish-
ness may make starting difficult or impossib-
le.
6.5 On/Off switch (8)
To switch on the compressor, pull out the On/Off
switch (8).
To switch off the compressor, press the On/Off
switch (8) in again. (Figure 2).
6.6 Setting the pressure (Fig. 1,2)
•
You can adjust the pressure on the pressure
gauge (6) using the pressure regulator (7).
•
The set pressure can be drawn from the
quick-lock coupling (5).
6.7 Setting the pressure switch
The pressure switch is set at the factory.
Cut-in pressure approx. 0,6 MPa (6 bar)
Cut-out pressure approx. 0,8 MPa (8 bar)