Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

DT162
OWNER'S MANUAL
Thank you for purchasing
the
Insect Trap!
DynaTrap
®
This product may be covered by one or more U.S. patents
or pending patent applications. See www.DynaTrap.com/patents
IMPORTANT: READ CAREFULLY
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS
WARNING:
when using electric appliances, basic precautions should
always be followed, including the following:
1.
Please read all instructions before using the DynaTrap
®
Insect Trap and keep for future reference.
2.
To disconnect, remove plug from outlet.
3.
To reduce the risk of injury from moving parts or electric shock, disconnect plug before servicing or cleaning.
4.
Always unplug before replacing lamp. Replace with same type rated 1.8-Watt UV-Light LED bulb, DynaTrap
5.
Do not position the unit near heat, gas, oil or other flammable materials.
6.
Place out of reach from children.
7.
To reduce the risk of electrical shock, do not put appliance in water or other liquid.
8.
Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or
if it has been dropped into water or other liquid.
9.
Connect only to a circuit that is protected by a ground-fault circuit-interrupter (GFCI).
10. Do not insert fingers or any foreign objects into the unit while it is connected to an electrical outlet.
11. Collected insects within the unit may contribute to fire, so clean insects from the unit frequently.
12. Do not clean this product with water spray. Do not place where it can fall into water, or near flammable materials.
13. Do not touch fan while in motion.
14. Do not abuse cord—never carry or hang unit by cord or yank it to disconnect from receptacle. Keep cord away from sharp edges.
15. If using outdoors, use only extension cords with a tag stating, "Suitable for Use with Outdoor Appliances."
16. Use only extension cords that have plug and receptacles that match the product plug. Replace or repair damaged cords.
17. Only use attachments recommended or sold by the manufacturer.
INSTALLATION & OPERATING INSTRUCTIONS
1.
Unpack unit. Save carton for off-season storage (if needed).
2.
The unit will turn on automatically when plugged in. For best catch results, leave the trap on and running, 24/7.
3.
Catch rate activity will be higher at night. For best catch results it is recommended to keep the unit away from competing light sources.
4.
It is recommended to place the unit at least 20 to 40 feet away from where people will be sitting.
5.
This unit is all-weather resistant - designed for outdoor use including rainy conditions.
6.
The electrical adapter provided with this product is equipped with a 2-conductor cord and a 2-prong plug as a safety feature.
If the plug does not fully fit in the outlet, contact a qualified electrician. To reduce the risk of electrical shock, only plug into a
properly installed outlet. Do not attempt to defeat this safety feature.
FCC COMPLIANCE
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation. CAUTION: Changes or modifications not approved by the party responsible for compliance could void user's authority to
operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
USER MAINTENANCE INSTRUCTIONS - CLEANING
Clean the trap at least once a week to prolong life of the unit, insure fire prevention, and provide for more efficient operation.
1.
Be sure to clean the unit once per week.
2.
Unplug before cleaning.
3.
For weekly cleaning, position collection bag (not included) beneath trap and press top of button on basket. Bottom of basket will
open to release collected insects. Seal bag and dispose of in accordance with local regulations. Brush any remaining residue from
basket door and push up until you hear the button click closed, and secure.
4.
For major cleaning, twist the basket clockwise to remove from upper housing. After removing, use a soft brush and remove any dirt
and debris from the fan housing. Remove the damper assembly from the basket by grasping the crossbar and pulling up firmly.
Remove any buildup from the inside of the basket and damper with a brush and replace damper by snapping firmly into place.
5.
When replacing the retaining cage – DO NOT press / push against the screen windows.
REPLACING BULB -
Replace With DynaTrap UV-LIGHT LED Bulb #11020 (or equivalent G24-Q2 Type - DC 9V/1.8 W UVA Bulb)
The UV-LIGHT LED light bulb life expectancy is approximately 20,000 hours (or about 2.25 years).
1. UNPLUG UNIT, and allow bulb to cool before replacing.
2. Remove screw
(A)
under cover, twist counter-clockwise and remove.
3. Grasp lamp housing and twist to remove (B). Note: Lamp houseing and lower sections will remain connected by electrical wire - Do
Not Pull or Attempt To Disconnect.
4. Cover the bulb
(C)
with a cloth to protect your fingers and hand. Grasp the bulb (with your hand and fingers protected by the cloth)
and gently pull the bulb from the socket.
5. Remove any debris from the lamp socket with a brush. Replace new bulb by aligning mark on base of bulb (D), with corresponding
(E)
to assure proper alignment. Replace lamp housing and twist to secure (C).
mark on socket
6. Replace cover and secure with screw (A).
®
model 11020.
REPLACEMENT PARTS
11020
1, UV-LIGHT LED Replacement Bulb, G24-Q2 Type - DC 9V/1.8W
To see all replacement and accessory parts available for your DynaTrap, visit www.DynaTrap.com.
HOW THE DYNATRAP
INSECT TRAP WORKS
®
Flying insects are attracted to the unit by UV light and CO2 that is
generated by the photo-catalysis between the UV-LIGHT LED lamp and
special TiO2 coating. The fan then pulls the insects into the screened
base, trapping them until they dehydrate and die. The base can be
removed, allowing the contents to be periodically emptied into the
trash.
TROUBLESHOOTING
Problem:
Possible cause:
Correction:
Bulb does not illuminate
No electrical power.
1. Check plug, receptacle and fuse or circuit breaker.
and fan does not spin.
Bulb illuminates, but fan
Shorted fan.
UNPLUG UNIT: Examine fan to see that it is free from
does not spin.
foreign material, dirt or buildup of dead insects.
Clean unit as in "CLEANING" section.
Fan spins, but bulb does
1. Bulb not seated
1. Check socket for proper bulb seating and alignment.
not illuminate.
properly
2. Burnt out bulb
2. Replace bulb following instructions under "Replacing Bulb"
LIMITED WARRANTY
DYNAMIC guarantees to the original purchaser that this product is free from defective materials and workmanship. This warranty is
limited to remedy any defective part for a period of one year from date of original date of purchase. Retain your original receipt
as proof of purchase. This warranty does not apply to the light bulb, nor to, in our judgment, misuse or abuse. If this unit has been
altered, no warranty is in force. This warranty does not apply if this unit is purchased outside the United States, excluding Canada
and Mexico. In no case shall DYNAMIC be liable for any accidental, punitive, consequential, or any other damages of any kind for
breach of this or any other warranty, expressed or implied, whatsoever. Some states do not allow limitation on how long an implied
warranty lasts, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may
also have other rights that vary from state to state.
SAVE THESE INSTRUCTIONS
FOR HOUSEHOLD AND COMMERCIAL,
INDOOR AND OUTDOOR USE
100 - 240 V~ 50/60 Hz 0.06 A max.
Dynamic Solutions Worldwide, LLC
69 N. Locust St., Lititz, PA 17543
1-877-403-8727 (TRAP)
dynatrap@woodstream.freshdesk.com
www.DynaTrap.com
This device complies with Performance Standards for
Light-Emitting Products, 21 CFR, Part 1040, Chapter 1,
© Dynamic Solutions Worldwide, LLC
UV-LED
BULB
TiO
2
COATING
FAN
RETAINING
CAGE
DAMPER FLAP
Subchapter J, Radiological health.

Publicidad

loading

Resumen de contenidos para DynaTrap DT162

  • Página 1 1. Check socket for proper bulb seating and alignment. REPLACING BULB - SAVE THESE INSTRUCTIONS Replace With DynaTrap UV-LIGHT LED Bulb #11020 (or equivalent G24-Q2 Type - DC 9V/1.8 W UVA Bulb) not illuminate. properly The UV-LIGHT LED light bulb life expectancy is approximately 20,000 hours (or about 2.25 years).
  • Página 2 Desenchufe siempre antes de reemplazar el foco. Reemplace con el mismo tipo de Foco LED de Luz Ultravioleta de 1.8 REEMPLAZO DEL FOCO - Reemplazar con DynaTrap Bulb # 11020 (o equivalente G24-Q2 Tipo - DC 9V/1.8 W Foco LED de Luz Ultravioleta) GARANTIA LIMITADA vatios DynaTrap modelo 11020.