x2
***
0---
10--
Add. 1ch
Add. 2ch
Add. 3ch
Add. 4ch
erase 64
erase 1
language
autoset
l. s w adj
o
stat
vers
OK
- +
No total manoeuvres(in hundreds)
n. cycles
OK
- +
No radio controldevices memorised
OK
n. remotes
- +
List of last 30 errors
err
OK
0---
password
22
BOTTICELLI SMART BT A 850-1250
ACCESS MENUS Fig. 2
150-
1520
See PARAMETERS MENU
See LOGIC MENU
ok
If cancelled
If not present
( 0001 )
KO
If clone, it is disabled
dis
Diagnostics
code
STRE
STRI
OPEN
CLS
PED
TIME
STOP
PHOT
PHOP
PHCL
BAR
BARc
BARo
SWC
SWO
SET
ER01
ER02
ER03
ER04
er06
ER1x*
ER3x*
Control unit
software version
ER4x*
bft . . .
ER70-ER71
+/-
ER74-ER75
0000
ER72
+/-
00
ER73
+/-
01
01. 3 3
02
02. 0 1
........
03
30. 1 5
+/-
* X = 0,1,...,9,A,B,C,D,E,F
10--
150-
ENGLISH
ok
See RADIO MENU
DESCRIPTION
START E external start input activated
START I internal start input activated
OPEN input activated
CLOSE input activated
PED pedestrian input activated
TIMER input activated
STOP input activated
PHOT photocell input activated
PHOT OP opening photocell input activated
PHOT CL closing photocell input activated
BAR safety edge input activated
Activation of edge input in BARC closure
Activation of edge input in BARO opening
SWC motor closing limit switch input activated
SWO motor opening limit switch input activated
The board is standing by to perform a complete open-
ing-closing cycle uninterrupted by intermediate stops
in order to acquire the torque required for movement.
WARNING! Obstacle detection not active
Photocell test failed
Safety edge test failed
Opening photocell test failed
Closing photocell test failed
8k2 safety edge test failed
Board hardware test error
Reverse due to obstacle - Amperostop
Thermal cutout
Internal system supervision control error.
Consistency error of the control unit's parameters
(Logics and Parameters)
D-track parameter error
Autoset not correctly performed due to intervention
of external commands. Repeat the procedure
Travel less than the minimum required travel,
about 50 cm.
The installation is too "resilient/oscillating". Tighten
it by adding a mechanical stop to the closure limit-
switch (kit code I100025 10005) before performing
a further autoset.
1520
*** Password entry.
Request with Protection Level
logic set to 1, 2, 3, 4
Scroll up
Scroll down
Con rm/Switch on display
Exit Menù
• Opening command
• ≥ 2 sec Manual transmitter programming as start
• Closure command
• ≥ 2 sec Manual transmitter programming as 2nd radio chan-
nel
• ≥ 5 sec Cancellation of remote controls
• Access menu
• ≥ 5 sec menu autoset
NOTES
Check photocell connection and/or logic settings
Check safety edge connection and/or logic settings
Check photocell connection and/or parameter/
logic setting
Check photocell connection and/or parameter/
logic setting
Check safety edge connection and/or parameter/
logic settings
- Check connections to motor
- Hardware problems with board (contact techni-
cal assistance)
Check for obstacles in path
Allow automated device to cool
Try switching the board off and back on again.
If the problem persists, contact the technical as-
sistance department.
Pressing OK the detected settings are confirmed. The
board will keep on working with the detected settings.
The board settings must be checked (Parame-
ters and Logics)
Pressing OK, the board will keep on working with
D-track as a default.
An autoset is required
prg