3.3.5
CHARGING AN EXTERNAL BATTERY
3.3.6
SWITCHING OFF
3.3.7
EMERGENCY STOP OF THE ENGINE
3.4.
Cleaning and maintenance
3.4.1 SERVICE INTERVALS TABLE
Action˅
Interval>
Drain
any
remaining fuel in
the fuel tank
Check the condition
of the oil in the
engine
Check for possible
engine oil leaks
With the generator off, connect the appropriate poles to the
battery poles ("+" - red, "-" black)
After starting the machine, the battery will start charging
automatically thanks to the built-in voltage regulator.
IMPORTANT: do not leave the battery connected to the
generator when it is not turned on.
Disconnect all current consumers.
Let it work without load for approx. 3 minutes to allow the
motor to cool down.
Switch off the engine with the starter button (2) or, in the
case of the MSW-AVR DG750 EURO5 model, set the starter
key (12) to the "OFF" position.
• Place the throttle lever in the "STOP" position. It is also an
alternative method of shutting down the motor (throttling).
In the event of an emergency or other dangerous situation,
the engine can be turned off with the emergency button (3)
on the control panel. Before restarting, this button must first
be returned to its original position, i.e. rotate it clockwise
until it pops out.
Every
month
Daily
after
operating
hours
(or before
any longer
disuse)
X
X
1
Every 3
or
months
20
or
100
working
hours
X
Every
six
Every year
months
or
or
500
1000
operating
operating
hours
hours
after