- Place the filter on a bin.
a) Remove the metal mesh filter by pulling it upwards. This filter can be washed with running water.
b) Take the HEPA filter and clean it as described below.
At least once a week, shake the HEPA filter in the bin to get the dirt out.
At least once every 2 months, carry out a more thorough cleaning: rinse HEPA filter, metal filter and
container with a soft brush and/or with warm water and DRY THEM THOROUGHLY.
CAUTION: Do not use detergent to clean the filter or the cover. The HEPA filter must be completely
dry before using the vacuum cleaner.
After cleaning:
-
Mount the metal filter on top of the HEPA filter, matching the mark on the plastic of the HEPA filter
with the recess in the metal filter.
-
Take the container and open the door.
-
Insert the filter in its housing and turn anticlockwise until it stops.
-
Close the door and refit the container to the motor body.
PROBLEMS AND SOLUTIONS
PROBLEM
The cleaner does not
work
Suction power is
weak
Dirt comes out of the
container
Unit cannot vacuum
MAINTENANCE AND CLEANING
CAUTION: before starting any operation, unplug the unit from the electrical outlet.
Normally this vacuum cleaner is not noisy. But when the dust container is full or the HEPA filter is clogged,
the noise emitted changes, so the suction power. In addition, thanks to the transparent container, you can see
the amount of dirt making it very easy to understand when you need to empty the container. Even the filters
should be cleaned periodically. These filters can also be damaged or exhausted (HEPA filter) and should be
replaced with new filters. Emptying the dust container and cleaning the filters as stated in this booklet, you
will avoid stressing the motor.
Clean the main body with a damp non-abrasive cloth, avoiding the use of aggressive detergents or abrasive
cleaners, which could ruin the aesthetic parts of the device.
The cloth should not be too wet, since the water penetrating the device, can seriously damage it. Cleaning
filters by following the specific instructions on this guide.
TECHNICAL FEATURES
Power supply: AC 220-240V
Dust capacity 0,7 lt
Vacuum 16 kPa
Accessories: telescopic tube, floor brush, multi-crevice nozzle
SPARE FILTERS: ask to your reseller the spare filter set, model G3FERRARI G90022
CAUSE
The unit is not correctly connected
Electricity is down.
The container is full.
The unit is obstructed..
Filters need to be cleaned.
Container is full.
Not correctly installed.
Broken container.
Blocked hose.
Dust container is full.
~
50-60Hz, 600W
SOLUTION
Plug the unit.
Check the distribution board.
Empty the container.
Unplug and check if something obstructs the unit
Clean or change the filter.
Empty the container and installi t again.
Replace the container.
Remove objects inside the hose.
Empty the container and clean the filters