Programming Overview
3-9
Menu-
No.
Entry
Selection
point
5
Key switch function (J7)
0*
Open/Close pulse input
1
Block control panel
2
Block external control elements
3
Block control panel and external control elements
50
4
Activating the control elements for 10 secs.
5
Switch to dead man's Close
6
Half Opening of the door only
7
Pulse input for Open-Stop-Close
Pulse input for Half Open-Stop-Close
8
9
Pulse input for (smoke-heat exhaust) (menu 55)
Function of external impulse generators
Three-button-control
51
0*
1
Open-Stop-Close function (J1.3 1/2-opening J1.4 full-opening)
52
001-256
Entering the control address
Plug-in module
53
off
0*
1, 2, 3
Actuation profiles, see plug-in module
Expansion control
54
0*
off
Actuation profiles, see extension control
1, 2, 3
55
Door setting for smoke-heat exhaust position
59
18
Do not change control version!
- -
Exit menu
6
Programming the START button on the transmitter
60
Programming button for 1/2-opening on the transmitter
61
Programming the light button on the transmitter
62
Deleting radio codes (press for 5 sec.)
63
- -
Exit menu
7
30*
Opening speed
71
20 - 65
Speed in rpm
Closing speed
20*
72
20 - 30
Speed in rpm
20*
Increased closing speed
73
20 - 30
Speed in rpm
Door setting change-over point
74
Acceleration time open
20*
75
10 - 30
x 0.1 sec
20*
Acceleration time close
76
10 - 30
x 0.1 sec
Braking time open
20*
77
10 - 30
x 0.1 sec
20*
Braking time close
78
10 - 30
x 0.1 sec
- -
Exit menu
Menu
30-
37
to
[73]
[72]
Item
1x
Menu-
No.
Entry
Selection
point
9
Selecting the door's service intervals
0*
no service interval
1
1000 cycles
2
4000 cycles
3
8000 cycles
4
12000 cycles
90
5
16000 cycles
6
20000 cycles
7
25000 cycles
8
30000 cycles
9
35000 cycles
10
40000 cycles
11
45000 cycles
12
50000 cycles
Issue of cycles counter
91
Issue of operating hours counter hours
96
Issue of error memory hours error code
97
-
Issue of software version
98
Resetting of factory setting (press for 5 sec.)
99
- -
Exit menu
Enter
-
-
cycles
-
-
-
-
-
serial-no. date
* Factory defaults