Switch (ON position)
Number
Switch 6
Position of the switch 6 is irrelevant.
Switch 7
Use the switch 7 to select the operating mode of the device:
OFF – INT-VG – full functionality,
ON – CA-64 SM – handling of notification messages only.
The INT-VG module is supported by the INTEGRA control panels with firmware version 1.10 (or
newer) and the VERSA control panels with firmware version 1.02 (or newer). The CA-64 SM
synthesizer is supported by the INTEGRA and VERSA control panels with any firmware version.
Only one module operating as INT-VG can be connected to the control panel.
If you need more than 16 notification messages, the second module connected to the control
panel must operate as CA-64 SM. The following control panels can notify of events by means
of 32 voice messages: INTEGRA 128, INTEGRA 128 Plus and INTEGRA 256 Plus.
Switch 8
The switch 8 is used to enable / disable the recording of messages by means of built-in microphone:
OFF – recording disabled,
ON – recording enabled.
2. Installation and start-up
Disconnect power before making any electrical connections.
1. Secure the module in the control panel enclosure.
2. Connect the CLK and DTA terminals to the corresponding terminals of the control panel
communication bus. Use an unshielded non-twisted cable.
3. Connect the PIN5 plug to the dedicated socket on the control panel electronics board.
4. Use the DIP-switches to set the module address and select the operating mode.
5. Power on the alarm system.
6. Start the identification function in the control panel (see the control panel installer manual).
The declaration of conformity may be consulted at www.satel.eu/ce