Names and functions of parts
Front panel
1Analog input connectors
These analog inputs are balanced XLR jacks.
i XLR (1: GND, 2: HOT, 3: COLD)
2INPUT SIG indicators
48V Indicators
These light when phantom power is on.
INPUT SIG indicators
These light when sound is being input through the
analog inputs.
Input is judged to have occurred when the signal level
exceeds -40 dBFS.
OL indicators
These light when analog input signals overload.
3OUTPUT SIG indicators
These light when sound is being output through the analog
outputs.
Output is judged to have occurred when the signal level
exceeds -40 dBFS.
4Analog output connectors
These analog outputs are XLR jacks.
i XLR (1: GND, 2: HOT, 3: COLD)
5DC POWER indicator
i This indicator will light when a DC power supply is
connected.
i This will blink to show that voltage is low when it
approaches the threshold voltage value set in advance on
the Sonicview 16/24 or using the TASCAM IO CONTROL
app.
See "Connecting the power" on page 11 for details.
STATUS indicator lighting status details
STATUS indicator
Ordinary operation
Lit blue
Malfunctioning (Dante)
Rapidly flashing red (four times per second)
Muted
Lit red
Dante network error
Flashing red (twice per second)
Dante redundancy error Blinking blue (once per second)
8
TASCAM SB-16D
6DC POWER button
i When operating only with DC power, press and hold this
button to turn the power on/off.
i Using this button is unnecessary when operating with AC
power because it will start up automatically.
See "Connecting the power" on page 11 for details.
7STATUS indicator
The STATUS indicator shows the state of the unit by lighting
blue or red or staying unlit.
See "STATUS indicator lighting status details" on page 8
for details.
8ID button
The device ID setting of this unit can be checked and
changed.
See "Device ID settings" on page 12 for setting procedures.
9SAMPLE RATE indicators
The lighting of the two SAMPLE RATE indicators (48 kHz/96
kHz) shows the sampling frequency state of the unit.
0PRIMARY/SECONDARY indicators
These light to show the Dante network status.
Communication is at 1 Gbps when lit and at 100 Mbps when
blinking.
Note
The unit is operating normally.
The Dante module is malfunctioning.
The indicator lights red when the clock is stabilizing
after the unit starts up and when the sampling
frequency or other Dante setting has been changed,
for example.
The Dante network is not connected.
The Dante PRIMARY connector is disconnected or
another error with redundant connection has occurred.

Publicidad

loading