Descargar Imprimir esta página

Lindy 38365 Manual De Usuario página 10

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

User Manual
English
Setting Page
The Setting Page includes two parts: Network and Login.
Network can be set to Static or DHCP. When is set to Static, IP address, gateway and subnet mask
can be entered; When set to DHCP, the IP address, gateway and subnet mask are grayed out and
cannot be changed.
A DHCP server (such as a network router) which automatically assigns IP related settings, should be
installed in the system. Web Port is the port of the Web page. Click on Save to confirm.
After setting the IP address, the page will automatically switch to the chosen IP address. Click on Set
Network Defaults to restore to the default DHCP state.
The Web login password can be changed on the Login part. Enter the old password in Old Password,
enter the new password in New Password, enter the new password again in Confirm Password, and
click on Save button to confirm.
Update Page
The SOC Update column is used to upgrade firmware. Click on Browse to select the firmware, and then
click on Update. When the progress bar reaches 100%, the upgrade is completed and the device will
restart automatically.
The IMG Update column is used to download the no-signal picture, click on Browse to select the picture
in jpg format (the resolution of the picture should be up to 1920x1080, the width should be aligned
with 8, the height should be aligned with 2, and the size of the picture should be less than 512kB), and
then click on Update. When the progress bar reaches 100%, the download is completed, and it will be
active on the device immediately, without rebooting.