NOTICE! The tank hose opening in the cap is NOT fluid tight. When transporting the LFM-
110 firstly remove the unused smoke fluid to prevent smoke fluid coming out and damaging
the LFM-110
Turning on the unit
!
NOTICE! Fire hazard
Do not operate the LFM -110BK unattended.
Connect the device to the mains and switch the device to "Light &FOG" with the
Power switch. Allow the unit heat up 5 – 6 minutes
As soon as the required operating temperature is reached, the green LED on the wired
control will light up, meaning the device is operational.
Operating:
When operating the fog machine, always ensures that there is sufficient fog liquid in the
liquid tank to avoid no-load running.
!
Operation with an empty liquid tank can lead to overheating and
permanent damage of the pump
!
WARNING: When the fog machine is in use don't touch the top of the
casing and the Fog nozzle on the front since they will get hot.
Never aim the fog nozzle directly on people within a range of 50cm when
in use. The ejected fog is very hot!
Turning the unit off
Allow the LFM-110BK to keep unused for several minutes before switching the Power
Switch to OFF. Turning off the power switch during fog production can cause damage to
the heat exchanger.
Allow the LFM-110BK to cool completely before packing/storing.
!
The nozzle of the LFM-110BK may remain hot for up to 10 minutes after
power is shut off.
Switch the device "OFF" with the Power switch. Disconnect the device from the mains.
Transport the device only when it is completely cooled down.
To avoid leaking fog Liquid during transport, you should transport the device only
with empty liquid tank.
WARNING
If the machine will be unused for an extended period of time, follow the Storage and
Shipment instructions listed under Maintenance to prepare the machine for long-
term storage.
8
OPERATING

Publicidad

loading