Installation and connection
B, C
• The unit can be placed submerged or dry.
• For installation above water: Ensure a safety distance of at least 50 cm from combustible material.
Do not cover the unit!
• Install the transformer at a minimum safety distance of 2 m from the water.
How to proceed:
1. Position the unit such that it does not present a hazard to anyone and the lamps are tilted as desired.
2. Connect the plug of the spotlight connection cable to the socket on the transformer and hand-tighten the union nut.
Commissioning/start-up
NOTE
The unit will be destroyed if it is operated with a dimmer. It contains sensitive electrical components.
Do not connect the unit to a dimmable power supply.
• Switching on: Plug the power plug into the outlet.
– The unit switches on immediately.
• Switching off: Pull the power plug from the outlet.
Maintenance and cleaning
Cleaning the LED spotlight
If necessary, clean the unit with clear water using a soft brush.
Repair work
The light source (LED) in the LED spotlight cannot be replaced.
Malfunction remedy
Malfunction
Lamp does not light up.
Illuminating power decreasing
Water inside the spotlight housing
Cause
Power supply interrupted
Lamp glass soiled
Seal defective
Remedy
Check power supply
Clean
Check the seal for correct seating and clean
- EN -
Fire hazard:
9