Descargar Imprimir esta página

GREENBLUE GB540 Manual Del Usuario página 4

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
Setting the channel: The weather station receives the outdoor sensor signal automatically
after you have made all the settings.Note: In the event of interference from nearby
equipment transmitting radio signals, the symbol for humidity (outdoor) and outdoor
temperature flashes during this time. Please select a different channel for the outdoor
sensor by pressing the "CH" button on the weather station or the channel selector switch
on the outdoor sensor. The relevant data is shown in the LCD display.-
1: Outdoor sensor channel 1 2: Outdoor sensor channel 2
3: Outdoor sensor channel 3 AUTO: automatic channel change
Displaying temperature and temperature trend: The current indoor temperature and the
temperature trend (indoors) are shown in the LCD display. After successfully connecting
with the outdoor sensor, the weather station can display the outdoor temperature and the
temperature trend (outdoor). You may see the following displays: The temperature is rising.
The temperature is remaining constant. The temperature is falling.
Displaying the humidity and humidity trend: The current humidity trend (indoors) and
the current humidity (indoors) are shown in the LCD display.The COMFORT indicator
displays the humidity in three categories.The following categories are available:
:| Humidity < 40% :) Humidity 40–70%, indoor temperature 20–28°C :( Humidity > 70%
After a successful connection has been made with the outdoor sensor, the weather station
shows the humidity trend (outdoors) and the humidity (outdoors) in the LCD display.
Displaying the maximum /minimum temperature /humidity: The minimum/maximum
temperature /humidity is measured for the first time after the batteries have been inserted
and stored in the weather station. The maximum and minimum values for temperature,
hygrometer and barometric pressure are automatically saved. • If the weather station is in
time display , press the "UP" button to display the maximum values. • Press the "UP"
button twice to display the minimum values. • Hold the "UP" button down for approx.
3 seconds to erase the stored maximum and minimum values.
Temperature and frost alarm: The temperature alarm is a short beep, which sounds
as soon as the outdoor temperature exceeds or falls below the preset temperature range.
Follow the below procedures to set the desired temperature range. • Press the "DOWN"
button to get top the temperature alarm mode. • Hold the "DOWN" button down for
3 seconds. The maximum temperature displays blinks. Press the "UP" or "DOWN" button
to set the values. • Press the "MODE" button to confirm your setting. The minimum
temperature displays blinks. Press the "UP" or "DOWN" button to set the values.
• Press the "MODE" button to confirm your setting.
Activating / deactivating the the temperature and frost alarm:
• If more than one outdoor sensor is activated, press the "CH" button to select one.
• Press the "DOWN" button repeatedly to activate the temperature and frost alarms.
If the frost alarm is activated, the corresponding symbol appears next to the outdoor
temperature. The alarm signal sounds at –1°C to + 3°C.
- 06 -
If the temperature alarm is activated, the corresponding symbol appears next to the
outdoor temperature. The alarm signal sounds at the set values.
If the temperature and frost alarm are activated, both symbols appear in the display.
Background lighting: When using the battery power supply, Press the "SNOOZE /LIGHT"
button. The backlight illuminates for 5 seconds. When using the DC-POWER power supply,
press "SNOOZE/LIGHT" button can choose high brightness / low brightness
Battery state display: If the "Indoor" column is display the battery icon "battery", you
need to replace the weather station's battery as soon as possible,
If the "Outdoor" column is to display the battery icon "battery", you need to replace the
wireless sensor battery of your channel as soon as possible based on the channel display.
PL
Bezprzewodowa Stacja Pogodowa
Opis części: Stacja pogodowa:
A1 Prognoza pogody
A2 Temperatura w pomieszczeniu (°C/ °F)
A3 Wskaźnik ciśnienia barometrycznego z ostatniej godziny A4 Wskaźnik komfortu
A5 Wilgotność (W pomieszczeniu) A6 Wskaźnik ciśnienia barometrycznego
A7 Faza księżyca A8 Wyświetlacz ciśnienia barometrycznego A9 Zegar
A10 Wybrany kanał A11 Alarm temperatury (maksymalna/minimalna)
A12 Temperatura na zewnątrz (°C/°F) A15 Ikony alarmów 1 i 2
A17 Symbol wieży radiowej i wyświetlacz DST (czas letni)
Obudowa: B1 Przycisk Tryb
B2 Przycisk Góra
B4 Drzemka/światło
B5 Przycisk Historia
B7 Przycisk Kontrast
B8 Otwór do zawieszenia
B10 Gniazdo zasilacza
B11 Komora baterii
DANE TECHNICZNE: Zakres pomiaru temperatury: 0 to +50°C
Rozdzielczość temperatury: 0.1°C Zakres pomiaru wilgotności: 20–95%
Rozdzielczość wilgotności: 1%
Sygnał radiowy:DCF Baterie: 2x AA, 1.5V
Zakres ciśnienia: 850- 1050hPa
Pasmo częstotliwości: 433.050 to 434.790MHz
Czujnik zewnętrzny: Zakres pomiaru temperatury: –20 to +65°C
Zakres pomiaru wilgotności: od 20% do 95% Rozdzielczość wilgotności: 1%
Sygnał transmisji RF: 433,92 MHz Zasięg transmisji: max. 60m. (w terenie otwartym)
Baterie: 2 x AA, 1.5 V
Przygotowanie do użycia czujnika zewnętrznego: • Zdejmij pokrywę komory baterii
z tyłu czujnika zewnętrznego. • Zdejmij pasek zabezpieczający baterię. Czujnik zewnętrzny
jest teraz gotowy do pracy, a kontrolka LED na chwilę się zapali. • Zamknij pokrywę.
Instalowanie czujnika zewnętrznego: Uwaga: do tego kroku będziesz potrzebować
wiertarki. • Znajdź odpowiednie miejsce dla czujnika zewnętrznego.
Uwaga: Upewnij się, że czujnik zewnętrzny został zainstalowany w promieniu 60m od
A16 Kalendarz
B3 Przycisk Dół
B6 Przycisk CH
B9 Ramka
-07-

Publicidad

loading

Productos relacionados para GREENBLUE GB540