8.4.
Service menu 35 - SM_P: Calibrating the heat-up phase
Calibrating the heat-up phase for switching on via remote start, preset time mode or the app.
D
Prerequisites:
Only carry out this process when the cabin and the sauna heater are cold.
Otherwise, the measured values will be distorted and the monitoring will not work
correctly during operation.
1.
Select menu 35.
D
The calibration process is started until a difference of 5 Kelvin is reached.
90 °C
D
If a difference of 5 Kelvin is reached, the measured time (e.g. 240 seconds) remains
the same.
-> Display of temperature 5.0 (Kelvin) and 240 (seconds).
2.
Press OK to confirm the displayed values.
3.
Select the END menu and press OK to confirm.