Liftmaster Quadro
Before using the vacuum lifting
system, read the operating instructions
completely.
It is prohibited to stand under the load.
06
06
03
03
04
04
19
19
20
20
18
18
4
Brief Instructions for Liftmaster Quadro Vacuum Lifting System
Always wear your personal protective
equipment and observe all safety
instructions.
If the warning siren and warning lights
signal a dangerous situation, the load
must be lowered immediately.
10
10
08
08
09
09
17
17
13
13
Switch on the lifting unit
• To check the correct condition of the second circuit, press the buttons (4) and (9) simultaneously (without
switching on the vacuum lifting unit). Warning siren, warning light(s) give signal when the battery of the
second circuit is sufficiently charged.
• Remove the battery cover (18) by first releasing both rubber bands (20). Push the supplied exchangeable
fully charged battery (13) into the receptacle until it engages and switch on the vacuum lifting unit at
the main switch (17).
Suction of a load
• Press the vacuum lifting unit against the load.
• Turn the vacuum on/off rotary switch (19) counterclockwise until it stops. The load is now sucked in and
the vacuum pump creates a vacuum between the suction plates and the load.
• The currently applied value is shown on the vacuum indicators (3) and (8). As soon as sufficient vacuum
has been generated and the alarm light and siren have gone out, the load can be lifted.
Rotate payload
• Pull the locking pin (6) and slowly turn the lifting unit to the desired position using the handles.
• Then release the locking pin and turn the vacuum lifting device minimally until the locking pin engages.
Swivelling the load
• To swivel from vertical to horizontal, loosen the locking bolt (10) and swivel the vacuum lifting unit by
the handles. For safety reasons, there is no locking point available in the horizontal position.
• To swivel the vacuum lifting device from the horizontal to the vertical, swivel it until the locking pin (10)
engages.
Releasing the load
• Lower the load carefully and secure the load against any kind of independent movement and external
influences (e.g. wind).
• Turn the rotary switch "Vacuum On/Off" (19) clockwise while pressing the button
go. The vacuum lifting unit is now ventilated.
• Once this is complete, the vacuum lifting unit can now be carefully removed from the load.