825P-850P DIGITAL PULSE OUTPUT METERS
Operational Functions
Turns meter on when off.
Displays accumulated total as long as it
is pressed. If accumulated total is larger
than 9999, the numbers will scroll across
the screen.
When held for 3 seconds, it resets current
total to zero. Also resets to normal operating
mode when in CAL or FLSH mode.
When held for 3 seconds, it allows changes to
the calibration factor displayed in the bottom
left corner. Repeated pressing will step the
number up to 19 and back to zero. When
desired number is displayed, press button
2
to lock in the new number and return to
normal operation.
When held for 3 seconds, flow rate is displayed.
Fluid dispensed is still added to the accumulated
total and current total. Press button
to normal operation.
Calibration Using the CAL Factor
The THINNER the fluid, the LOWER the CAL number.
The THICKER the fluid, the HIGHER the CAL number.
CAL 4 is set for thin fluids like water.
CAL 19, the highest number, is set for very thick fluids like
cold molasses.
Each number changes the meter accuracy by about 1%.
Table #1: Suggested CAL Factor Settings for Common Fluids
0
1
2
3
4
NOTE: The suggested CAL factors are for REFERENCE ONLY.
sotera.com
4
to return
5
6
7
8
9
INSTALLATION AND OPERATION MANUAL
Use
CAUTION
Meter will count air if you dispense air. Before initial
operation or when air has entered the system, prime
the meter by dispensing fluid until all trapped air has
been removed. Meter is now ready to operate.
1. Press
button to turn meter on. Current total, unit of
measure, and calibration factor are displayed. The meter
also turns on automatically and begins recording when
fluid starts flowing through it.
2. Hold button
2
for one second to reset current total
to "0.00."
3. Begin dispensing.
NOTE: Meter display automatically goes blank after 60
seconds of inactivity and automatically comes back on when
flow resumes. No data is lost during periods of inactivity.
CAUTION
Wear proper safety equipment when handling
hazardous fluids.