Chapitre 1: Connections and Configuration
inches (1.2 meters) deep, bury the rod horizontally at least 2 feet (600 millimeters) below ground
level.
CAUTION
2. Connect a 12 AWG gauge, insulated or bare, copper conductor cable to the grounding rod.
3. Connect the other end of the 12 AWG gauge, insulated or bare, copper conductor cable to the earth
ground terminal on the board.
Schematic Diagram
8
The rod must be at least 5/8 inches (1.6 centimeters) in diameter and at least 10
feet (3 meters) long, and free of paint, enamel or other non-conductive
substances.