Chapitre 1: Connections and Configuration
Connecting the Sensors
Before You Begin
To avoid electrical shorts when connecting the equipment to the terminals provided, strip the wires as little
as possible, or about one quarter inch (7 millimeters).
1. Once the circuits are wired, run them through the electrical knockout holes on the bottom of the
enclosure.
NOTICE
2. Use a cable holder to make the unit water tight.
3. Connect each sensor circuit to a Z terminal and to a COM terminal.
NOTE: Each COM terminal is used by two zones. For example, Z1 and Z2 use the same COM.
CAUTION
Connecting the Programmable Outputs
The module has an output that can be activated automatically if the system is configured accordingly. The
output can also be activated over the phone or using the keypad.
1. Run a wire from the load's positive terminal to the positive terminal on the battery.
2. If more than one load is used, run a wire from the other load positive terminals to the +SBV terminal
on the module's board.
3. Run a wire from the load's negative terminal to the PGM terminal on the module's board.
4. Run a wire from the GND terminal to the negative terminal of the battery.
Figure 1-1 Three examples of load connections
10
Do not make additional holes in the enclosure. Failure to comply voids warranty
without further notice.
Make sure each sensor is connected to the correct COM. Failure to do so might
result in false alerts.
895-00397 TP-800