Descargar Imprimir esta página

HEIDENHAIN EIB 5000 Serie Modo De Empleo página 54

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 131
5.9
Connecting the shield of the sensor
Route the sensor shield separately for the EIB 5181 (see
X108). The metallic connecting elements ensure proper
shielding for the EIB 52xx variants.
Comply with the pin layout
Route the cable based on the mounting variant
Connect the cable to the respective connection
Connect the shield on both sides such that a low-
impedance connection over a large area is ensured
Keep the wires short for the connection
Figure 8: Recommended connection with interrupted cable
shield
54
B
A
5.10 DIP switch
With the EIB 5181 variant, you can use the DIP switches
to define its mode of operation.
Adjust the following setting parameters to the
requirements of the application:
Connected temperature sensors
Time constant for temperature measurement
Emulation of the temperature output
Setting the DIP switches
Observe the following setting parameters
Set the switches to ON or OFF
The DIP switches are located on the top of the EIB 5181.
Note the arrangement of the DIP switches.
Sensor type 1
S1.3
S1.2
S1.1
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
HEIDENHAIN | EIB 5000 | Operating Instructions | 04/2021
Function
KTY84-130
PT1000
PTC
PTC triplet
Reserved
Reserved
KTY84-130 with a common
reference
No sensor

Publicidad

loading

Este manual también es adecuado para:

Eib 5181Eib 5211Eib 5212Eib 5281Eib 5282Eib 5291s