5.3 Technical data table

MODEL
119
Powers
Pmax
Pmin
Heating Capacity (Net
kW
131
Heat Value - Hi)
Useful Heating Power
kW
119
Gas supply
Pmax
Pmin
Pilot nozzle G20
mm
1 x 0.40
Pilot nozzle G31
mm
1 x 0.24
Main nozzles G20
mm
7 x 3.40
Supply pressure G20
mbar
20
Pressure at burner G20
mbar
13.3
Delivery G20
m3/h
13.8
Main nozzles G31
mm
7 x 2.15
Supply pressure G31
mbar
37
Pressure at burner G31
mbar
36
Delivery G31
kg/h
10.26
Heating
Max. working tempera-
°C
100
ture
Max. working pressure in
bar
6
heating
No. elements
8
Min. working pressure in
bar
0.4
heating
No. burner trains
7
Boiler water content
litres
38
Weight
Weight with packing
kg
470
Electrical power supply
Max. electrical input
W
32
Power voltage/frequency
V/Hz
230/50
Electrical protection rat-
IP
X0D
ing
MODEL
187
Powers
Pmax
Pmin
Heating Capacity (Net
kW
206
Heat Value - Hi)
Useful Heating Capacity
kW
187
Gas supply
Pmax
Pmin
Pilot nozzle G20
mm
1 x 0.40
Pilot nozzle G31
mm
1 x 0.24
Main nozzles G20
mm
11 x 3.40
Supply pressure G20
mbar
20
Pressure at burner G20
mbar
13.3
Delivery G20
m3/h
21.8
Main nozzles G31
mm
11 x 2.15
Supply pressure G31
mbar
37
Pressure at burner G31
mbar
36
Delivery G31
kg/h
16.31
Heating
Max. working tempera-
°C
100
ture
Max. working pressure in
bar
6
heating
No. elements
12
Min. working pressure in
bar
0.4
heating
No. burner trains
11
Boiler water content
litres
54
Weight
Weight with packing
kg
665
Electrical power supply
Max. electrical input
W
32
Power voltage/frequency
V/Hz
230/50
Electrical protection rat-
IP
X0D
ing
136
153
Pmax
Pmin
Pmax
Pmin
77
149
89
168
100
71
136
82
153
92
Pmax
Pmin
Pmax
Pmin
1 x 0.40
1 x 0.40
1 x 0.24
1 x 0.24
8 x 3.40
9 x 3.40
20
20
4.8
13.3
4.8
13.3
4.8
8.1
15.8
9.4
17.9
10.6
8 x 2.15
9 x 2.15
37
37
11.4
36
11.4
36
11.4
6.0
11.6
6.9
13.2
7.8
100
100
6
6
9
10
0.4
0.4
8
9
42
46
530
575
32
60
230/50
230/50
X0D
X0D
221
255
Pmax
Pmin
Pmax
Pmin
122
243
144
280
166
112
221
133
255
153
Pmax
Pmin
Pmax
Pmin
1 x 0.40
1 x 0.40
1 x 0.24
1 x 0.24
13 x 3.40
15 x 3.40
20
20
4.8
13.3
4.8
13.3
4.8
12.9
25.7
15.2
29.6
17.6
13 x 2.15
15 x 2.15
37
37
11.4
36
11.4
36
11.4
9.5
19.0
11.2
21.92
12.9
100
100
6
6
14
16
0.4
0.4
13
15
62
70
760
875
32
60
230/50
230/50
X0D
X0D
5.4 Diagrams
Pressure loss
6
170
5
Pmax
Pmin
187
110
4
170
102
Pmax
Pmin
3
1 x 0.40
1 x 0.24
10 x 3.40
2
20
13.3
4.8
19.8
11.6
10 x 2.15
A
37
36
11.4
1
14.64
8.6
0.9
0.8
100
0.7
0.6
6
0.5
11
0.4
0.4
10
0.3
50
625
0.2
60
3
230/50
X0D
Key
A
Pressure losses m H
289
B
Delivery m
Pmax
Pmin
317
188
289
173
Pmax
Pmin
1 x 0.40
1 x 0.24
17 x 3.40
20
13.3
4.8
33.5
19.9
17 x 2.15
37
36
11.4
24.82
14.6
100
6
18
0.4
17
78
945
60
230/50
X0D
cod. 3540T624 - Rev. 02 - 11/2018
4
5
6 7 8 9 10
B
O column
2
3
/h
20
30
40
37
EN

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Pegasus f3 n 136 2sPegasus f3 n 153 2sPegasus f3 n 170 2sPegasus f3 n 187 2sPegasus f3 n 221 2sPegasus f3 n 255 2s ... Mostrar todo

Tabla de contenido