Descargar Imprimir esta página

MSW -DEH3090H Manual De Instrucciones página 27

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 87
The dryer will automatically start defrosting for 15 minutes.
LED
defrosting indicator flashes.
The compressor stops and the fan continues to run.
Do not turn off the unit, it will automatically resume dehumidification.
Overload protection
In the event of a power loss, there is a 3-minute delay until the compressor restarts,
which protects the compressor.
3.3.3. Water drainage
There are two ways to dispose of the collected water produced by the unit:
Manual draining: Drain the water tank manually.
Continuous drainage: use gravity to drain the water through the drain hose to
the outside of the unit.
Emptying the water tank
The device will turn off when the water tank is full. The dehumidifier will work again
after emptying the water tank and installing it correctly.
1) When the tank is full, the "FULL
2) The device will be beeping. Press the power button to turn off the device.
3) To empty the water tank, open the front panel to access it.
4) Grasp the handle of the water tank and pull it out horizontally.
5) After the water has been removed, install the tank and close the front panel.
6) Press the POWER | ON/OFF button to restart the unit.
3.3.4. Error codes
Error code
E1
E2 & E3
Overload
Error
The problem with the coil
Problem with the humidity sensor
1. False error
2. Refrigerant leakage
" light will come on.
Solution
Replace the coil
Replace the sensor
1. Switch the devices off
2. Check the unit for
and on again after 2
minutes
refrigerant leakage

Publicidad

loading

Este manual también es adecuado para:

Msw-deh3120hMsw-deh4090hMsw-deh3090