Check if the water level indicator is
lit.
Check the ambient temperature
Check if the air filter is clean
The
Check if the airway is not obstructed
formation of
Check if the ambient temperature is
condensate
below 20°C
is low.
The set humidity level is higher than
current humidity.
Leakage when moving the unit
Water leak
Make sure the drain hose is not
twisted
Check that the device is properly set
up
Excessive
Check the unit for loose, vibrating
noise
parts
Noise similar to the flow of water
Empty the water tank and
install it correctly
The operating range of the
ambient temperature is 5-
35°C
Clean
the
air
necessary
Unblock it if necessary
It is normal. Low humidity at
low ambient temperature
Set the humidity level below
the current humidity.
Empty the water tank before
transporting the unit
Straighten
the
necessary
Correct the placement of the
device
Secure loose parts
Noise
from
refrigerant. It is normal
filter
if
hose
if
flowing