Descargar Imprimir esta página

Velleman HQ-POWER VDL500SM Manual Del Usuario página 4

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

• Familiarise yourself with the functions of the device before actually using it. Do not allow operation by
unqualified people. Any damage that may occur will most probably be due to unprofessional use of the
device.
• Use the original packaging if the device is to be transported.
• All modifications of the device are forbidden for safety reasons.
• Only use the device for its intended purpose. Other uses may lead to short circuits, burns,
electroshocks etc. Using the device in an unauthorised way will void the warranty.
4. Description
Refer to the illustrations on page 2.
1
power ON/OFF switch
2
fuse
3
indicator light
4
smoke generation switch
5. Installation
a) Smoke Liquid
• Unplug the device before filling the tank.
• Please use non-inflammable water-based smoke fluid without oil or grease, such as VDLSL1 (1 litre),
VDLSL5 (5 litres), or VDLSL5H (5 litres high density smoke liquid).
• Non-recommended smoke liquid may damage the machine and void the warranty.
1. Unplug the device from the mains.
2. Unscrew the cap from the tank.
3. Carefully pour smoke liquid into the tank (do not overfill it!!).
4. Screw the cap closed.
Remark: Do not operate the device when the tank is open.
b) Fuse
• Only fit or replace a fuse when the device is unplugged from the mains.
• Replace a blown fuse with a fuse of the same type and rating (see "8. Technical Specifications"):
1. Unplug the device from the mains.
2. Unscrew the fuse holder at the back with an appropriate screwdriver.
3. Remove the old fuse and install a new one.
4. Replace the fuse holder and fasten it with the screwdriver.
c) Mounting the Device
• Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable
norms.
• The construction to which the device is attached should be able to support 10 times the weight of the
device for one hour without deformation.
• The installation must always be secured with a secondary attachment e.g. a safety cable (e.g.
VDLSC7 or VDLSC8).
• Never stand directly below the device when it is being mounted, removed or serviced. Have a qualified
technician check the device once a year and once before you bring it into service.
• Install the device in a location with few passers-by that is inaccessible to unauthorised persons.
• Overhead mounting requires extensive experience: calculating workload limits, determining the
installation material to be used... Have the material and the device itself checked regularly. Do not
attempt to install the device yourself if you lack these qualifications as improper installation may result
in injuries.
• Make sure there is no flammable material within a 50cm radius of the device.
• Have a qualified electrician carry out the electric connection.
• Connect the device to the mains with the power plug. Don't connect it to a dimming pack.
• The installation has to be approved by an expert before the device is taken into service.
6. Use
Connect the device to the mains and flick the power switch at the back of the device to ON. After the
warm-up time (approx. 5-8 minutes) the device is ready for use. The green indicator light is now lit:
• Activate/deactivate the smoke output with the push button.
23.12.2010
VDL500SM
5
hot nozzle
6
adjustable handle
7
feeder tube
8
liquid tank with cap
4
Rev. 01
©Velleman nv

Publicidad