LCD shows
000.00 mm /
00.000 in
Function keys do
not work
Calliper does not
measure
accurately
No display on LCD
screen
7.
Technical Specifications
data output
maximum measuring
speed
display
battery
operating temperature
storage temperature
operating humidity
V. 01 – 23/08/2016
3472
One of the keys is
short circuited
Key spring is bent
or deformed
Sensor is dirty
1.
No battery
contact.
2.
Battery
voltage is
under 1.1 V.
serial output for interface with host
computer or printer
1.5 m/sec or 60"/sec
LCD, features minus sign "-", character
in 6.35 mm / 0.25" height for 5 digits,
small digit "5" and "IN" indication for
inch measuring unit
1x 1.5 V silver oxide battery for one
year of continuous use
low-battery warning by flashing display
0°C +40°C
-20°C +70°C
0 to 80%
6
Remove the cover
and adjust key
spring position
Remove the cover
and adjust key
spring position
Remove the cover
and slider
assembly, clean
the sensor with
pressure air
( 51 kg/cm²),
and clean it with a
little petrol for dirt
prevention.
1.
Restore
battery
contact.
2.
Replace
battery
©Velleman nv