Turn the tattoo machine off com-
E
pletely.
Check if the machine has become
E
heavily contaminated by the return
flow of inks or bodily fluids. In such
cases, perform the steps described in
chapter 7.3 on page 39 .
Wipe down the machine cables, the
E
drive and the grip with a soft cloth
moistened with disinfectant.
5.3
Connecting the power unit
CAUTION
Risk of short-circuit
If cable or cable connection is visibly dam-
aged, there is a risk of damage to the elec-
tronics.
Perform a visual inspection of the tat-
E
too machine and the cable for signs of
damage, e.g. a defective cable connec-
tion.
Never bend the connecting cable while
E
in operation.
Observe the operating manual for the
E
particular power unit.
34 EN
CAUTION
Cables constitute a trip hazard
People may stumble over inappropriately
routed cables and get injured.
Route all cables so that no-one can
E
stumble over them or pull them acci-
dentally.
There are three ways to supply power to
the machine:
Cable
adapters
provided
1.
Connecting it to a Cheyenne power
unit with the connecting cable pro-
vided in the scope of delivery (rec-
ommended).
2.
Connection to a third-party power
unit with the 6.3 mm jack and the
cable adapter supplied. The exter-
nal power unit must deliver ap-
prox. 6 to 12.5 V DC direct current
and the required start-up current
indicated
in
chapter  4.1  on
page 32. If more than about 13.5 V
is connected to the machine, it will
shut down automatically.
3.
Connection to an external power
supply using the optionally avail-
able Y-cable adapter with banana
plugs. The red banana plug must
be connected to the positive termi-
nal while the black banana plug
must be connected to the negative
terminal of the third-party power
unit.
Connect the socket of the connecting
E
cable from the scope of supply to the
connection on the drive unit of the
machine.
Plug the jack of the machine cable
E
fully into the output socket on the
power unit. If you are using the third
party power unit, connect its termi-
nals correctly, as described in the op-
erating instructions of the third party
power unit.
Cheyenne HAWK Pen Unio