4. LCD Display Operating Instructions
NO.
Item
Automatic restart due
24
to excessive
temperature
25
Buzzer alarm
26
Mode change reminder
27
Inverter overload to skip
Maximum AC charging current
28
29
Qutput Phase Split Function
30
Model ID Settings
AC output mode (set to
31
standby mode only)
Configuration Options
[24] DIS
[24] ENA non-compliance
[25] DIS
[25] ENA non-compliance
[26] DIS
[26] ENA non-compliance
[27] DIS
[27] ENA non-compliance
[28] unpaid
[29] Default DIS
[29] ENA.
[31] 1 unpaid
[31] SIG.
[31] PAL Default
[31] 2P0/2P1/2P2.
ll machine screens connected to P1 must be set to "2P0"; assuming the output voltage set
by the setting element [38] is 120 VAC (U-series mocels).
1) When the display of all machines connected to P2 is set to "2P1", the voltage phase
difference between P1 and P2 is 120 degrees, and the voltage between the live L1 cable of
the P1 phase anc the live L2 cable of the P2 phase is 120 * 1,732 = 208 Vac; the voltage
between L1-N, L2-N is 120 Vac. 2) When the screens of all machines connected to P2 are
set to "2P2", the voltage phase difference between P1 and P2 is 180 degrees, and the
voltage between the live L1 cable of P1 phase and the live L2 cable of P2 phase is
120*2=240Vac; the voltage between L1-N, L2-N is 120Vac
80
Description
Automatic over-temperature reset is prohibited, if
over temperature occurs, the output will be turned off
and the machine will no longer turn on the output.
Enable automatic over-temperature reset, if
over temperature occurs, the output will be turned off,
and the output will be reset when the temperature drops.
Prohibit Alarm
Alarm On
When the status of the primary input source
changes, the alarm message is prohibited.
Enable alarm alert when primary input source status
Changes.
When the inverter is overloaded, it is forbidden to
automatically cut the network.
Automatically switch to the network when the inverter
is overloaded.
Maximum AC charging current setting. For U series
models, the adjustment range is O0~40A, and the
default value is 40A; for S series models, the
adjustment range is O~60A, and the default value is
60A.
Disable this feature.
Enable Power Frequency Transformer Output.
The parallel mode shall be set in the range 1-6.
Single Use Settings (for U and S Series models).
Single-phase parallel use settings (for U and S series
models).
Two-phase parallel use settings (U-Series models
only).