DMX CONTROL
To control the device using a DMX controller:
-
Select the desired DMX operation mode: 1 or 3 channels as shown in the table above. Use the MODE
and SET button to select the number of channels and press ENTER to confirm the setting.
-
Select the DMX address to control this LED bar with a value between 1 and 512. Use the MODE and SET
button to select the DMX address and press ENTER to confirm the setting.
-
Below are the features of each channel in the different DMX operating modes:
1 channel (d):
CHANNEL
3 channels (A):
CHANNEL
-
It is possible to cascade several devices to be managed together (if they are in the same DMX address)
or separately (if they are in different DMX addresses).
Use an XLR cable to connect the device's DMX IN to the DMX OUT of the DMX controller when the
device is the first element in the chain. Alternatively, connect to the DMX OUT of the preceding element
in the lighting chain of your installation.
DMX CONTROLLER
To interconnect them, you must use XLR cables with the following configuration:
IMPORTANT: the complete length of cable used to interconnect the devices in a line must not exceed 100
meters. To prevent line interference, it is recommended that an electric terminator consisting of a 120 Ω
resistor be placed at the last element in the chain between pins 2 and 3 of the XLR DMX OUT connector of
the last element.
VALUE
CH1
000-255
VALUE
CH1
000-255
CH2
000-255
CH3
000-255
GND
POWER IN
~110-240 V AC. 50/60 Hz FUSE: 5 A
POWER CONSUMPTION: 60 W
MODE
SET
DMX IN
DMX OUT
DMX IN
DMX OUT
GND
POWER IN
~110-240 V AC. 50/60 Hz FUSE: 5 A
POWER CONSUMPTION: 60 W
MODE
SET
DMX IN
DMX OUT
DMX IN
DMX OUT
GND
POWER IN
~110-240 V AC. 50/60 Hz FUSE: 5 A
POWER CONSUMPTION: 60 W
MODE
SET
DMX IN
DMX OUT
DMX IN
Ground
Male XLR (pin view)
FUNCTION
Light intensity
FUNCTION
Overall light intensity
Strobe speed
Light intensity
1
2
Signal +
3
Signal -
- 3 -
EN
BAR-73L
LED BAR 24 x 3 W
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION : SHOCK HAZARD - DO NOT OPEN
RISK OF FIRE-REPLACE FUSE AS MARKED
POWER OUT
4 A MAX.
BAR-73L
LED BAR 24 x 3 W
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION : SHOCK HAZARD - DO NOT OPEN
RISK OF FIRE-REPLACE FUSE AS MARKED
POWER OUT
4 A MAX.
BAR-73L
LED BAR 24 x 3 W
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION : SHOCK HAZARD - DO NOT OPEN
RISK OF FIRE-REPLACE FUSE AS MARKED
POWER OUT
4 A MAX.