Dispensing in AUTO mode.
• To start dispensing:
Pull the trigger
completely and then
release it.
The trigger thus
remains locked in
open position. Now
dispensing can
continue even if the
Operator is not
present.
• To stop manually dispensing in
progress:
Pull again the trigger completely and
then release it.
• The dispensing operation can be
resumed in AUTO mode within a given
time (TIME OUT) from the stop. Within
this TIME OUT the METER still allows the
locking of the trigger in open position.
• After this TIME OUT the METER still
allows the user to continue the
dispensing but only in MANUAL mode.
• Automatic stop:
The supply automatically stops when
the pre-set value is reached. The AUTO
message disappears from the LCD.
• Manual resumption of the
dispensing (TOPPING UP):
Once dispensing has been carried out in
AUTO mode, the METER allows the user
to continue the dispensing operation, if
necessary.
Warning
Some time after the automatic stop of
dispensing, the METER 2)
lights up and dispalys the preset
quantity and the value.
To carry out the TOPPING UP, DO
NOT type RESET and pull the trigger.
The dispensed amount is added to the
previous one in AUTO mode.
The PRESET value previously set,
displayed in the Total, starts blinking to
indicate that the pre-set value has been
exceeded.
Blinking value.
23