Technical Data
Code
Description
Chuck
Voltage
Frequency
Current
Functions
Power
Strokes per minute
Speed
Work Capacity
Duty Cycle
Conductors
Insulation
WARNING
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
WARNING
Power Requirements
Tools with double insulation and reinforced insulation are
WARNING
equipped with a polarized plug (one prong is wider than the other). This plug will
only fit in the right way into a polarized outlet. If the plug cannot be introduced into
the outlet, reverse the plug. If it still doesn't fit, call a qualified electrician to install
for you a polarized outlet. Do not alter the plug in any way. Both insulation types
eliminates the need of both a grounded third power cord with three prongs or a
grounded power connection.
When using an extension cable, verify the gauge is enough for
WARNING
the power that your product needs. A lower gauge cable will cause voltage drop in the line, resulting in power loss and
overheating. The following table shows the right size to use depending on cable's length and the ampere capability shown in
the tool's nameplate. When in doubt use the next higher gauge.
Ampere
Capacity
From 0 A and up to 10 A
From 10 A and up to 13 A
From 13 A and up to 15 A
From 15 A and up to 20 A
WARNING
When operating power tools outdoors, use a
extension cable labeled "For Outdoors Use". These extensions are especially designed for
operating outdoors and reduce the risk of electric shock.
50 minutes' work per 20 minutes idle. Maximum 6 hours per day
Class II
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
Before gaining access to the terminals all power sources should be disconnected.
Number of
Conductors
3 (one grounded)
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge - Reference NMX-J-195-ANCE
ROTO-1/2N6
19457
Hammer Drill
1/2"
127 V
60 Hz
5 A
Drill | Hammer drill
0.93 Hp
0 49, 600 strokes/min
0 - 3 100 RPM
Steel: 3/8" | Wood: 1" | Concrete: 1/2"
18 AWG x 2C with insulating temperature of 221 °F
IP Grade
Power Cord Grips used in this product: Type "Y".
Tool Build Quality: Reinforced Insulation
Thermal insulation on motor winding: Class B
Extension Gauge
From 6 ft to 49 ft
18 AWG
16 AWG
14 AWG
8 AWG
IP20
Authorized Service Center.
|
Higher than 49 ft
16 AWG
14 AWG
12 AWG
6 AWG
grounded
ENGLISH
3