USING YOUR ICE MAKER
1. Open the cover, remove the ice basket and pour water into tank. Keep water level below
the water level mark.
2. Press "ON/OFF" button on the control panel to begin the ice making cycle.
3. Select the ice cube size by pressing the "SELECT" button. If the room temperature is
lower than 15℃(59℉), it is recommended to select small ice cube in order to avoid ice
sticking together.
4. The ice making cycle lasts approx. 6 to 13 minutes, depending on selection of ice cube
size and the room temperature. The recommended room temperature is 10℃ to 38℃
(50 ℉ to 100 ℉)
5. If water pump can't inject water, the ice maker will stop automatically, and the "ADD
WATER" indicator will be on. Press "ON/OFF" button, fill water up to the max. water level
mark and press "ON/OFF" button again to turn on the unit again. Allow the refrigerant
liquid inside the compressor at least 3 minutes to settle before restarting.
6. The ice maker stops when the ice basket is full and the "ICE FULL" indicator will be on.
Warning: Direct sunlight or sunlight reflection may cause infrared sensor
malfunction. If the unit doesn't stop even ice cubes obstruct sensor, move the unit
where no sunlight.
7. Change water in the water reservoir every 24 hours to ensure a reasonable hygiene
level.
If unit isn't to be used, drain all the water and dry the tank.
TROUBLESHOOTING
PROBLEM
"ADD WATER"
indicator is on.
"ICE FULL" indicator is
on.
Ice cubes stick
together.
Ice making cycle is
normal but no ice
formed.
POSSIBLE CAUSE
Lack of Water.
Ice is full in basket.
The ice making cycle is
too long.
Water temperature in
inner tank is too low.
Room temperature or
water temperature in
inner tank is too high.
Refrigerant in cooling
system leaks.
Pipe in the cooling
system is blocked.
8
SOLUTION
Stop the ice maker, fill water, and
press "ON/OFF" button again to
restart the unit.
Remove ice from ice basket.
Continuous press "Select" button 5
seconds, the unit could make ice 10
cycles even "Ice" indicator is on.
Stop the ice maker, and restart it
when the ice blocks melt. Select the
small size ice cube selection.
Replace the water. Temperature of
water recommended at 8-32℃(46℉-
90℉)
The room temperature should be 5-
43℃(41-110℉), water temperature
should be 8-32℃ (46℉-90℉).
Verify by a qualified technician.