Descargar Imprimir esta página

FGMatic EURO380 M1 Instrucciones De Uso página 6

Cuadro electronico para 1 motor 380vac

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

GB
ACCESSORIES
••••
OPTIONS SELECTOR
OPTION 1 - Automatic closing
ON
Door closes automatically after waiting the a.c.time
OFF
Door does not close automatically
OPTION 2 - Disable stop on opening
ON
Opening the alternative button is disabled
OFF
If alternative button is pressed door stops
OPTION 3 - Radio open/Alternative
ON
Radio card works as alternative button
OFF
Radio card works as a opener
OPTION 4 - DeadMan
ON
DeadMan functionality enabled
OFF
DeadMan functionality disabled
OPTION 5 - Double time
ON
Working time range from 1m10sec to 2m10sec
OFF
working time range from 6-8secs to 1m25sec
OPTION 6 - Garage light
ON
Garage lights goes on when the door is opening
OFF
2 secs impulse
OPTION 7 - Safety edge photocell
ON
Door inverts during 1 sec. During opening and closing.
OFF
During opening, safety opening activates
OPTION 8 - Pre-flashing
ON
Flashing output ENABLED before starting, open and close
OFF
Flashing output DISABLED before starting, open and close
Instruction Manual
( EURO380 M1 )
SAFETY
OPERATING INSTRUCTIONS
The control panel can be activated by Test CI P.ALTER), via the radio card, or by the open, close and stop buttons.
Manoeuvres can be finalised via the following: limit switch activation or end of working time
If the ALT button is pushed while the door is opening it stops and does not close the door.
Pressing the STOP button stops the door. It is necessary to push OPEN or CLOSE buttons to reactivate the operation.
If the safety input is activated whilst the door is closing then the door will open.
The garage light contact is activated when the door is opening & deactivated after 2 seconds.
If I4 is ON y I3 ON the control panel gives the order for automatic opening and closing of the dead mans switch.
If I4 is ON y I3 OFF the control panel gives the order to open and close the dead mans switch.
WARNING!!
AN ACCESSIBLE SWITCH, TO TURN OFF THE EQUIPMENT,MUST BE INSTALLED FOR SYSTEMS
THAT ARE ALWAYS CONNECTED.
BEFORE INSTALLING MAKE SURE THE SUPPLY VOLTAGE IS SWITCHED OFF.
SETTINGS
••
OPTIONAL
NOT AVAILABLE
STANDARD

Publicidad

loading

Este manual también es adecuado para:

E107