Descargar Imprimir esta página

Lamborghini Caloreclima ALHENA TECH H Serie Instrucciones De Uso, Instalación Y Mantenimiento página 355

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ALHENA TECH H
4.6 Wiring diagram
16 Fan
32 Heating circulating pump
34 Heating temperature sensor
44 Gas valve
72 Room thermostat (not supplied)
81 Ionization/ignition electrode
95 Diverter valve
138 External probe (optional)
44
X04-8
X04-9
230V
X04-1
50Hz
GROUND
95
X04-5
X04-6
X04-7
288
16
X01-3
X01-4
X01-5
X01-6
X01-7
Attention: Remove the jumper from terminals 5-6 on the terminal block before connecting
A
the room thermostat or the remote timer control.
To connect more zones of the hydraulic system controlled by thermostats with voltage-free
contact and the timer control has to be used for remote control of the boiler, the voltage-
free contacts of the zones must be connected to terminals 1-2 and the timer control to ter-
minals 5-6.
ALL CONNECTIONS TO THE TERMINAL BLOCK MUST BE WITH VOLTAGE-FREE
CONTACTS (NOT 230V).
EN
32
X05
8
1
9
1
X07
X11
LC32
fig. 66- Wiring diagram
cod. 3541V622 - Rev 00 - 05/2022
139 Remote timer control (optional)
155 Hot water tank probe (optional)
186 Return sensor
191 Fume temperature sensor
288 Frost protection kit
294 Pressure transducer
ON/OFF switch (configurable)
A
191
34
186
14
1
5
1
X08
X16
X09
1.2
bar
45
°C
294
25
°C
N
L
138
A
5
6
1.8kOhm
10kOhm
81
72
139
155
355

Publicidad

loading