Never paint the unit. Paint may prevent smoke from entering the unit. If you are planning renov-
ations or repainting, contact your installer and ask that the unit be temporarily removed until
work is complete.
If the unit is located in an area where it is exposed to high levels of dust or insects and causes false
alarms, it may require service; contact your smoke detector installer or dealer.
Specifications
Diameter: 5 in (125 mm)
l
Height: 2.5 in (63 mm)
l
Weight (including battery): 8.75 oz (243 g)
l
Color: White
l
Spacing rating: 70 ft (21.3 m)
l
Alarm Sensitivity (threshold): complies with EN14604
l
Audible Signal (ANSI Temporal 3): 85dBA min. in alarm
l
Evacuation Temporal Pattern
l
Operating Temperature: 0°C to 55°C (32°F to 131°F)
l
Operating Temperature with Heat Detector: 32ºF-100ºF (0º-37.8ºC)
l
Humidity: 93% RH, non-condensing
l
Approved Batteries for ASD30: 3 AAA Duracell Procell MN2400
l
Supervisory Transmission Frequency : 12 minute intervals
l
Low Battery Detection: Low battery 14 days remaining
l