X-LINE SOURCES AND CHARGERS - INSTRUCTION MANUAL
CONSUMPTION - MINIMUM CABLE GAUGE - POWER
Max.
Model
Consumption
X-LINE
entry
40A
600W
60A
900W
70A
1050W
120A
1800W
150A
2250W
200A
3000W
TECHNICAL SPECIFICATIONS
AC input
Consumption with maximum load
Maximum output current
Selectable output voltage
SCI - Intelligent charging system
3-phase slow load system - Customizable
Smart cooler - Smart ventilation system
Precision voltmeter / ammeter
Protections
Dimensions L x A x P (mm)
Weight Kg
AC input
Consumption with maximum load
Maximum output current
Selectable output voltage
SCI - Intelligent charging system
3-phase slow load system - Customizable
Smart cooler - Smart ventilation system
Precision voltmeter / ammeter
Protections
Dimensions L x A x P (mm)
Weight Kg
AC input cable
Network
Network
127Vac
220Vac
(up to 10 meters)
5A
3A
7A
4A
8A
5A
15A
8A
18A
10A
24A
14A
X-LINE 40A
90 to 140Vac / 170 to 240Vac (Automatic Bi-volt)
600W
40 Amperes
12,6V / 13,0V / 13,4V / 13,8V / 14,0V / 14,4V
13,8 / 14,4 cyclic
Elevation /Absorption/ Equalization
Dynamic control by PWM
99% / 96%
Excesso de carga / Curto na saída / Temperatura
259 x 151 x 58
1,420
X-LINE 60A
90 to 140Vac / 170 to 240Vac (Automatic Bi-volt)
900W
60 Amperes
12,6V / 13,0V / 13,4V / 13,8V / 14,0V / 14,4V
13,8 / 14,4 cyclic
Elevation /Absorption/ Equalization
Dynamic control by PWM
99% / 96%
Overload / Short at output / Temperature
259 x 151 x 58
1,440
DC output cable
(up to 1 meter)
2,5mm2
6mm2
4mm2
10mm2
4mm2
16mm2
4mm2
25mm2
6mm2
35mm2
6mm2
50mm2
Max power.
Output
40A
60A
70A
120A
150A
200A