security
Made in Italy
2014/35/EU LVD
Double element pyroelectric sensor
Local alarm memory signallization
Automatic sensibility according to changes of temperature
"Pulse counter" function with automatic reset
2 "Pulse counter" function settable
Antiopening protection tamper
High immunity RF 30Vm
Power supply voltage12-24 Vdc ±10%
Max current consumption 15mA
Beams of the lens 43
Levels of the lens 3
Coverage angle 360°
Coverage max.8mt
Escludible signalling LED
Solid state NC 100mA, 50Vdc max. relay outputs
Initial stabilizing time 60''
Operating temperature +5°C ÷ 40°C
Safety degree: 1
Ambiental class: 2
Dimensions (H) 31mm
Dimensions (Ø) 85mm
Approved directives CEI EN 50131-1
INSTALLATION
Install the detector to a height of 3,2mt approximately for having one cover of approximately 4mt of
beam; the installation to an inferior height makes to diminish the protection beam, while the installation to a
advanced height to the 4mt. it can mean one total insufficiency to the ends of the protection.
Do not install on surfaces
subject to vibration
Do not install towards sources
of heat or air conditioners
Lead free
Pb
Ceiling volumetric passive infrared detector
RoHS
compliant
Do not install towards windows
and balconies
Do not interpose objects or piece
of furniture in the detection beam
IR364
Vertical detection scheme
3m
4m
0m
Schema di rilevazione orizzontale
4m
3